Details

Calibrating, Counters, Electron Counters, Fabrication, Flux (Rate), Particle Telescopes, Scintillation, Coincidence Circuits, Compressing, Counting Circuits, Crystals, Plastics, Rates (Per Time), Ripples

Scientific paper

A satellite borne High Energy Electron Analyzer has been designed to measure electrons in the range of 1 MeV to 10 MeV. Very low background from omnidirectional charged particles is achieved with two Solid State Detectors and a BGO scintillator crystal arranged in a telescope unit and with the requirement of a triple coincidence of electrons in the measurement range. Ten energy bins are provided by the BGO over this range. Additionally, electron singles above 10 MeV and proton singles above 15.7 MeV are measured by the BGO crystal. The Solid State Detectors also provide measurements for proton singles from 4.1 MeV to 269 MeV. The background is further reduced by a plastic scintillator, surrounding the BGO, and placed into anticoincidence with the electron measurement. A complete electron energy spectrum plus singles measurement is generated every .512 seconds. The higher count rates from 3.5 to 1000 kcps are accommodated with compression counters while the lower count rates are accumulated in straight ripple counters. Three different coincidence requirements (Front SSD coincidence, Back SSD coincidence, Shield anticoincidence) are selectable by ground command. Two instruments have been fabricated, tested and calibrated. The first of these has been integrated on the CRRES satellite and is currently undergoing spacecraft testing at BASD.

No associations

LandOfFree

Say what you really think

Search LandOfFree.com for scientists and scientific papers. Rate them and share your experience with other people.

Rating

Design, fabricate, calibrate, test and deliver two satellite electron flux detectors does not yet have a rating. At this time, there are no reviews or comments for this scientific paper.

If you have personal experience with Design, fabricate, calibrate, test and deliver two satellite electron flux detectors, we encourage you to share that experience with our LandOfFree.com community. Your opinion is very important and Design, fabricate, calibrate, test and deliver two satellite electron flux detectors will most certainly appreciate the feedback.

Rate now

     

Profile ID: LFWR-SCP-O-1818984

  Search
All data on this website is collected from public sources. Our data reflects the most accurate information available at the time of publication.