Design and Testing of a Prototype Pixellated CZT Detector and Shield for Hard X-Ray Astronomy

Astronomy and Astrophysics – Astrophysics

Scientific paper

Rate now

  [ 0.00 ] – not rated yet Voters 0   Comments 0

Details

9 pages LaTeX, 10 figures, to appear in Proc. SPIE 3765, "EUV, X-Ray, and Gamma-Ray Instrumentation for Astronomy X"

Scientific paper

We report on the design and laboratory testing of a prototype imaging CZT detector intended for balloon flight testing in April 2000. The detector tests several key techniques needed for the construction of large-area CZT arrays, as required for proposed hard X-ray astronomy missions. Two 10 mm x 10 mm x 5 mm CZT detectors, each with a 4 x 4 array of 1.9 mm pixels on a 2.5 mm pitch, will be mounted in a ``flip-chip'' fashion on a printed circuit board carrier card; the detectors will be placed 0.3 mm apart in a tiled configuration such that the pixel pitch is preserved across both crystals. One detector is eV Products high-pressure Bridgman CZT, and the other is IMARAD horizontal Bridgman material. Both detectors are read out by a 32-channel VA-TA ASIC controlled by a PC/104 single-board computer. A passive shield/collimator surrounded by plastic scintillator surrounds the detectors on five sides and provides a ~45 deg field of view. The background spectrum recorded by this instrument will be compared to that measured by a single-element CZT detector (10 mm x 10 mm x 2 mm high-pressure Bridgman material from eV Products) fitted with the same passive/plastic collimator but including an active BGO shield to the rear. This detector has been previously flown by us completely shielded by a passive cover. We describe preliminary laboratory results for the various systems, discuss initial background simulations, and describe our plans for balloon flight tests.

No associations

LandOfFree

Say what you really think

Search LandOfFree.com for scientists and scientific papers. Rate them and share your experience with other people.

Rating

Design and Testing of a Prototype Pixellated CZT Detector and Shield for Hard X-Ray Astronomy does not yet have a rating. At this time, there are no reviews or comments for this scientific paper.

If you have personal experience with Design and Testing of a Prototype Pixellated CZT Detector and Shield for Hard X-Ray Astronomy, we encourage you to share that experience with our LandOfFree.com community. Your opinion is very important and Design and Testing of a Prototype Pixellated CZT Detector and Shield for Hard X-Ray Astronomy will most certainly appreciate the feedback.

Rate now

     

Profile ID: LFWR-SCP-O-105440

  Search
All data on this website is collected from public sources. Our data reflects the most accurate information available at the time of publication.