Design, analysis and test of a microdots apodizer for the Apodized Pupil Lyot Coronagraph

Astronomy and Astrophysics – Astrophysics

Scientific paper

Rate now

  [ 0.00 ] – not rated yet Voters 0   Comments 0

Details

A&A accepted, 8 pages

Scientific paper

10.1051/0004-6361:200810918

Coronagraphic techniques are required to detect exoplanets with future Extremely Large Telescopes. One concept, the Apodized Pupil Lyot Coronagraph (APLC), is combining an apodizer in the entrance aperture and a Lyot opaque mask in the focal plane. This paper presents the manufacturing and tests of a microdots apodizer optimized for the near IR. The intent of this work is to demonstrate the feasibility and performance of binary apodizers for the APLC. This study is also relevant for any coronagraph using amplitude pupil apodization. A binary apodizer has been designed using a halftone dot process, where the binary array of pixels with either 0% or 100% transmission is calculated to fit the required continuous transmission, i.e. local transmission control is obtained by varying the relative density of the opaque and transparent pixels. An error diffusion algorithm was used to optimize the distribution of pixels that best approximates the required field transmission. The prototype was tested with a coronagraphic setup in the near IR. The transmission profile of the prototype agrees with the theoretical shape within 3% and is achromatic. The observed apodized and coronagraphic images are consistent with theory. However, binary apodizers introduce high frequency noise that is a function of the pixel size. Numerical simulations were used to specify pixel size in order to minimize this effect, and validated by experiment. This paper demonstrates that binary apodizers are well suited for being used in high contrast imaging coronagraphs. The correct choice of pixel size is important and must be adressed considering the scientific field of view.

No associations

LandOfFree

Say what you really think

Search LandOfFree.com for scientists and scientific papers. Rate them and share your experience with other people.

Rating

Design, analysis and test of a microdots apodizer for the Apodized Pupil Lyot Coronagraph does not yet have a rating. At this time, there are no reviews or comments for this scientific paper.

If you have personal experience with Design, analysis and test of a microdots apodizer for the Apodized Pupil Lyot Coronagraph, we encourage you to share that experience with our LandOfFree.com community. Your opinion is very important and Design, analysis and test of a microdots apodizer for the Apodized Pupil Lyot Coronagraph will most certainly appreciate the feedback.

Rate now

     

Profile ID: LFWR-SCP-O-456997

  Search
All data on this website is collected from public sources. Our data reflects the most accurate information available at the time of publication.