Cross-calibration Of The X-ray Instruments Onboard The Chandra, Suzaku, Swift, And XMM-Newton Observatories Using 1E 0102.2-7219

Astronomy and Astrophysics – Astronomy

Scientific paper

Rate now

  [ 0.00 ] – not rated yet Voters 0   Comments 0

Details

Scientific paper

The flight calibration of the spectral response of CCD instruments below 1.5 keV is difficult in general because of the lack of strong lines in the on-board calibration sources. This calibration is also a function of time due to the effects of radiation damage on the CCDs and/or the accumulation of a contamination layer on the filters or CCDs. We desire a simple comparison of the absolute effective areas of the current generation of CCD instruments in the 0.5-1.0 keV range, specifically: Chandra ACIS, XMM-Newton EPIC (MOS and pn), Suzaku XIS, and Swift XRT. We have been using 1E 0102.2-7219 (hereafter E0102) since it has strong lines of O, Ne, and Mg below 1.5 keV and little or no Fe emission. The spectrum of E0102 has been well-characterized using the RGS grating instrument on XMM-Newton and the HETG grating instrument on Chandra. We have developed an empirical model for E0102 that includes Gaussians for the identified lines, two absorption components (one for the Galaxy and one for the SMC), and two continuum components with different temperatures. In our fits, the model is highly constrained in that only the normalizations of the four brightest line complexes (the O VII triplet, the O VIII Ly-α line, the Ne IX triplet, and the Ne X Ly-α line) and an overall normalization are allowed to vary. In our previous study in 2008, we found that most of the fitted line normalizations agreed to within +/- 10% (28 of 32 line normalizations). We have now expanded this study to include more recent data from these missions using the latest calibration updates and we will report on the current level of agreement amongst these instruments.
This work is based on the activities of the International Astronomical
Consortium for High Energy Calibration (IACHEC).

No associations

LandOfFree

Say what you really think

Search LandOfFree.com for scientists and scientific papers. Rate them and share your experience with other people.

Rating

Cross-calibration Of The X-ray Instruments Onboard The Chandra, Suzaku, Swift, And XMM-Newton Observatories Using 1E 0102.2-7219 does not yet have a rating. At this time, there are no reviews or comments for this scientific paper.

If you have personal experience with Cross-calibration Of The X-ray Instruments Onboard The Chandra, Suzaku, Swift, And XMM-Newton Observatories Using 1E 0102.2-7219, we encourage you to share that experience with our LandOfFree.com community. Your opinion is very important and Cross-calibration Of The X-ray Instruments Onboard The Chandra, Suzaku, Swift, And XMM-Newton Observatories Using 1E 0102.2-7219 will most certainly appreciate the feedback.

Rate now

     

Profile ID: LFWR-SCP-O-1403649

  Search
All data on this website is collected from public sources. Our data reflects the most accurate information available at the time of publication.