Other
Scientific paper
Mar 2008
adsabs.harvard.edu/cgi-bin/nph-data_query?bibcode=2008ycat..21720099c&link_type=abstract
VizieR On-line Data Catalog: J/ApJS/172/99. Originally published in: 2007ApJS..172...99C
Other
2
Surveys, Photometry: Ubv, Photometry: Sdss, Photometry: Hst
Scientific paper
The present COSMOS data were collected on a variety of telescopes and instruments, as well as from the Sloan Digital Sky Survey (SDSS) second data release (DR2) archive (u, g, r, i, z) and Hubble Space Telescope (HST, F814W). This paper covers the processing of the data obtained with Suprime-Cam on the Subaru 8.3m telescope (Bj, Vj, g+, r+, i+, z+, NB816), Megaprime on the 3.6m Canada-France-Hawaii Telescope (CFHT, u*, i*), FLAMINGOS on the Kitt Peak National Observatory (KPNO, Ks) 4m telescope, and the Infrared Side Port Imager on the Cerro Tololo Inter-American Observatory (CTIO, Ks) 4m telescope during the 2004-2005 observing season.
The COSMOS I band catalog is an I band selected multi-color catalog for 2 square degrees centered on the COSMOS field at 10:00:28.6, +02:12:21.
The total magnitude (SExtractor mag_auto) for a source must have an AB magnitude of less than i+<25 to appear in the archival catalog. All photometry is in the AB magnitude system and measured in a 3 arc second aperture on PSF-matched images unless otherwise noted. A magnitude of -99 indicates a photometric measurement was not possible due to lack of data, a large number of bad pixels, or saturation. A magnitude of 99.0 indicates no detection. In the case of no detection the error given for the object is the 1 sigma limiting magnitude at the position of the souce.
The photometry is as measured on the images with no corrections applied. We recommend applying the magnitude offsets in the paper to obtain the best possible photometry. More details on the photometry are available in the paper. The Photometric Redshifts included in this catalog are described in Mobasher et al. (2007ApJS..172..117M) and have an accuracy of dz/(1+z)<0.031 at z<1.2 and I<24.
It is important to pay attention to the flag columns at the end of the catalog. The cleanest catalog will have all flags set to 0. The photometry flags indicate the area of the photometry aperture, in square arc seconds, which is in a masked region. A flag of 1 indicates 14 percent of the aperture is masked, so any flagged object should be carefully checked. Objects with a de-blending flag set to 1 are potentially spurious and should not be used for statistical studies. However, the photometry for real sources with a de-blending flag set to 1 is good if they fall outside of masked region.
(1 data file).
Ajiki Masaru
Aussel Herve
Blain Andrew W.
Brusa Marcella
Capak Peter
No associations
LandOfFree
COSMOS Multi-Wavelength Photometry Catalog (Capak+, 2007) does not yet have a rating. At this time, there are no reviews or comments for this scientific paper.
If you have personal experience with COSMOS Multi-Wavelength Photometry Catalog (Capak+, 2007), we encourage you to share that experience with our LandOfFree.com community. Your opinion is very important and COSMOS Multi-Wavelength Photometry Catalog (Capak+, 2007) will most certainly appreciate the feedback.
Profile ID: LFWR-SCP-O-886307