Astronomy and Astrophysics – Astronomy
Scientific paper
Aug 2005
adsabs.harvard.edu/cgi-bin/nph-data_query?bibcode=2005spie.5898..341k&link_type=abstract
UV, X-Ray, and Gamma-Ray Space Instrumentation for Astronomy XIV. Edited by Siegmund, Oswald H. W. Proceedings of the SPIE, Vol
Astronomy and Astrophysics
Astronomy
4
Scientific paper
The Swift X-ray Telescope (XRT) is a CCD based X-ray telescope designed for localization, spectroscopy and long term light curve monitoring of Gamma-Ray Bursts and their X-ray afterglows. Shortly after launch there was a failure of the thermo-electric cooler on the XRT CCD. Due to this the Swift XRT Team had the unexpected challenge of ensuring that the CCD temperature stayed below -50C utilizing only passive cooling through a radiator mounted on the side of the Swift. Here we show that the temperature of the XRT CCD is correlated with the average elevation of the Earth above the XRT radiator, which is in turn related to the targets that Swift observes in an orbit. In order to maximize passive cooling of the XRT CCD, the XRT team devised several novel methods for ensuring that the XRT radiator's exposure to the Earth was minimized to ensure efficient cooling. These methods include: picking targets on the sky for Swift to point at which are known to put the spacecraft into a good orientation for maximizing XRT cooling; biasing the spacecraft roll angle to point the XRT radiator away from the Earth as much as possible; utilizing time in the SAA, in which all of the instruments on-board Swift are non-operational, to point at "cold targets" and restricting observing time on "warm" targets to only the periods at which the spacecraft is in a favorable orientation for cooling. By doing this at the observation planning stage we have been able to minimize the heating of the CCD and maintain the XRT as a fully operational scientific instrument, without compromising the science goals of the Swift mission.
Abbey Anthony F.
Beardmore Andrew
Burrows David N.
Campana Sergio
Chester McMath M.
No associations
LandOfFree
Controlling the Swift XRT CCD temperature via passive cooling does not yet have a rating. At this time, there are no reviews or comments for this scientific paper.
If you have personal experience with Controlling the Swift XRT CCD temperature via passive cooling, we encourage you to share that experience with our LandOfFree.com community. Your opinion is very important and Controlling the Swift XRT CCD temperature via passive cooling will most certainly appreciate the feedback.