Computer Science
Scientific paper
Dec 1992
adsabs.harvard.edu/cgi-bin/nph-data_query?bibcode=1992spie.1734..249a&link_type=abstract
In: Gamma-ray detectors; Proceedings of the Meeting, San Diego, CA, July 21, 22, 1992 (A93-30101 11-35), p. 249-260.
Computer Science
Compton Effect, Energy Spectra, Gamma Rays, Image Reconstruction, Radiation Detectors, Electron Density (Concentration), High Resolution, Monte Carlo Method
Scientific paper
A method for imaging a target with Compton scattered gamma radiation is presented. This method accepts simultaneously, in the detector energy spectrum, radiation scattered from the entire target in a single measurement. The energy spectrum provides the information necessary for reconstructing the electron density distribution within the target. Models on which the reconstruction process is based are presented and tested against Monte Carlo simulation and experimental data. Image reconstruction from simulations demonstrate the feasibility of the method. The problems encountered in reconstructing images from experimental spectra are addressed along with some workable solutions.
Arendtsz Nina V.
Hussein Esam M. A.
No associations
LandOfFree
Compton scatter imaging with energy sensitive high resolution detectors does not yet have a rating. At this time, there are no reviews or comments for this scientific paper.
If you have personal experience with Compton scatter imaging with energy sensitive high resolution detectors, we encourage you to share that experience with our LandOfFree.com community. Your opinion is very important and Compton scatter imaging with energy sensitive high resolution detectors will most certainly appreciate the feedback.
Profile ID: LFWR-SCP-O-1143382