Complete Pb/U analysis of unspiked samples by measuring Pb isotopes only

Mathematics – Logic

Scientific paper

Rate now

  [ 0.00 ] – not rated yet Voters 0   Comments 0

Details

Scientific paper

For the analysis of samples with a complex Pb-loss history during their geological evolution, the measurement of single grains without chemical separation and spiking of their U and Pb is desirable. In such cases a 207Pb/206Pb age can only be determined if concordant 206Pb/238U and 207U/235U ages are assumed. Because of the completely different ionisation behavior of Pb and U, the Pb/U ratio cannot be obtained. In radioactive equilibrium, however, 238U and 210Pb are present in a fixed ratio of 210Pb/238U = 238λ/210λ = 5 . 10-9 so that, in principle, the Pb/U measurement can be replaced by an isotope abundance ratio 210 Pb Pb. A sample with a (concordant) age of 300 Ma corresponding to a 206Pb/238U ratio of 4.76 . 10-2 would, for example, have a 210Pb/206Pbr ratio of 1.05 . 10-7.
Using a Finnigan MAT 262 mass spectrometer with variable multicollector arrangement, masses 204, 206, 207 and 208 were measured simultaneously with Faraday cups, while mass 210 was determined with an electron multiplier (SEM) in ion counting mode (IC). The system was calibrated by means of artificial mixtures, with 210Pb/206Pb ratios of 10-3, 10-4, 10-5, 10-6 and 10-7. The 208Pb abundance sensitivity to mass 210 is 1.7 . 10-7. The accuracy of the 210Pb/206Pb method was tested by comparison of data obtained by the conventional isotope dilution technique with those obtained by our 210Pb/206Pb method for different tobernite samples, and good agreement was recorded.

No associations

LandOfFree

Say what you really think

Search LandOfFree.com for scientists and scientific papers. Rate them and share your experience with other people.

Rating

Complete Pb/U analysis of unspiked samples by measuring Pb isotopes only does not yet have a rating. At this time, there are no reviews or comments for this scientific paper.

If you have personal experience with Complete Pb/U analysis of unspiked samples by measuring Pb isotopes only, we encourage you to share that experience with our LandOfFree.com community. Your opinion is very important and Complete Pb/U analysis of unspiked samples by measuring Pb isotopes only will most certainly appreciate the feedback.

Rate now

     

Profile ID: LFWR-SCP-O-1537888

  Search
All data on this website is collected from public sources. Our data reflects the most accurate information available at the time of publication.