Comparison of source detection procedures for XMM-Newton images

Astronomy and Astrophysics – Astrophysics

Scientific paper

Rate now

  [ 0.00 ] – not rated yet Voters 0   Comments 0

Details

20 pages, 16 figures. Accepted for publication in A&A

Scientific paper

10.1051/0004-6361:20010264

Procedures based on current methods to detect sources in X-ray images are applied to simulated XMM images. All significant instrumental effects are taken into account, and two kinds of sources are considered -- unresolved sources represented by the telescope PSF and extended ones represented by a b-profile model. Different sets of test cases with controlled and realistic input configurations are constructed in order to analyze the influence of confusion on the source analysis and also to choose the best methods and strategies to resolve the difficulties. In the general case of point-like and extended objects the mixed approach of multiresolution (wavelet) filtering and subsequent detection by SExtractor gives the best results. In ideal cases of isolated sources, flux errors are within 15-20%. The maximum likelihood technique outperforms the others for point-like sources when the PSF model used in the fit is the same as in the images. However, the number of spurious detections is quite large. The classification using the half-light radius and SExtractor stellarity index is succesful in more than 98% of the cases. This suggests that average luminosity clusters of galaxies (L_[2-10] ~ 3x10^{44} erg/s) can be detected at redshifts greater than 1.5 for moderate exposure times in the energy band below 5 keV, provided that there is no confusion or blending by nearby sources. We find also that with the best current available packages, confusion and completeness problems start to appear at fluxes around 6x10^{-16} erg/s/cm^2 in [0.5-2] keV band for XMM deep surveys.

No associations

LandOfFree

Say what you really think

Search LandOfFree.com for scientists and scientific papers. Rate them and share your experience with other people.

Rating

Comparison of source detection procedures for XMM-Newton images does not yet have a rating. At this time, there are no reviews or comments for this scientific paper.

If you have personal experience with Comparison of source detection procedures for XMM-Newton images, we encourage you to share that experience with our LandOfFree.com community. Your opinion is very important and Comparison of source detection procedures for XMM-Newton images will most certainly appreciate the feedback.

Rate now

     

Profile ID: LFWR-SCP-O-133619

  Search
All data on this website is collected from public sources. Our data reflects the most accurate information available at the time of publication.