Comparison of bar and interferometer sensitivities to sources of transient gravitational radiation

Astronomy and Astrophysics – Astrophysics

Scientific paper

Rate now

  [ 0.00 ] – not rated yet Voters 0   Comments 0

Details

10

Scientific paper

The signal-to-noise ratios for the detection of gravitational radiation are derived and compared for resonant bar and laser interferometric detectors. The results presented here apply to the detection of transient gravitational radiation as would be emitted in particlendashblack-hole interactions, stellar collapse events, or the decay of compact binary systems. For the detection of fixed-energy gravitational-wave bursts, the bar antenna shows its resonant nature with a sensitivity that is broadly peaked near the bar frequency, while the interferometer response shows a smooth f-1 dependence. Applied to the detection of the radiation emitted in the decay of a compact binary system, the ratio of bar to interferometer sensitivities is independent of source parameters. Using operational antenna parameters (circa 1985), the 4.2-K Stanford bar (Td=20 mK, Ma=4.8×103 kg, La=3 m, fa=840 Hz) is shown to be typically three times more sensitive to transient sources than the 30-m interferometer (h~=2×10-19/ √Hz above 500 Hz) at the Max-Planck-Institut für Quantenoptik in Garching, West Germany. Additionally, the signal-to-noise ratios calculated here are normalized to represent optimistic Galactic sources (located at 10 kpc, 10-2 Msolarc2 emitted in a gravitational burst) and indicate that both antennas are operating near astrophysically interesting sensitivities with signal-to-noise ratios ranging from 1 to 10 for these sources.

No associations

LandOfFree

Say what you really think

Search LandOfFree.com for scientists and scientific papers. Rate them and share your experience with other people.

Rating

Comparison of bar and interferometer sensitivities to sources of transient gravitational radiation does not yet have a rating. At this time, there are no reviews or comments for this scientific paper.

If you have personal experience with Comparison of bar and interferometer sensitivities to sources of transient gravitational radiation, we encourage you to share that experience with our LandOfFree.com community. Your opinion is very important and Comparison of bar and interferometer sensitivities to sources of transient gravitational radiation will most certainly appreciate the feedback.

Rate now

     

Profile ID: LFWR-SCP-O-1677521

  Search
All data on this website is collected from public sources. Our data reflects the most accurate information available at the time of publication.