Astronomy and Astrophysics – Astrophysics
Scientific paper
2008-06-11
Astrophys.J. 685:958,2008
Astronomy and Astrophysics
Astrophysics
28 pages, 8 Postscript figures (low resolution). Accepted for publication in the ApJ
Scientific paper
10.1086/591015
We have studied the correlation between 2357 Chandra X-ray point sources in a 40 x 40 parsec field and ~20,000 infrared sources we observed in the corresponding subset of our 2 x 1.4 degree Spitzer/IRAC Galactic Center Survey at 3.6-8.0 um, using various spatial and X-ray hardness thresholds. The correlation was determined for source separations of less than 0.5", 1" or 2". Only the soft X-ray sources show any correlation with infrared point sources on these scales, and that correlation is very weak. The upper limit on hard X-ray sources that have infrared counterparts is <1.7% (3 sigma). However, because of the confusion limit of the IR catalog, we only detect IR sources with absolute magnitudes < ~1. As a result, a stronger correlation with fainter sources cannot be ruled out. Only one compact infrared source, IRS 13, coincides with any of the dozen prominent X-ray emission features in the 3 x 3 parsec region centered on Sgr A*, and the diffuse X-ray and infrared emission around Sgr A* seems to be anti-correlated on a few-arcsecond scale. We compare our results with previous identifications of near-infrared companions to Chandra X-ray sources.
Arendt Richard G.
Cotera Angela S.
Gezari Daniel Ysa
Law Casey J.
Moseley Samuel Harvey
No associations
LandOfFree
Comparison of 3.6 - 8.0 Micron Spitzer/IRAC Galactic Center Survey Point Sources with Chandra X-Ray Point Sources in the Central 40x40 Parsecs does not yet have a rating. At this time, there are no reviews or comments for this scientific paper.
If you have personal experience with Comparison of 3.6 - 8.0 Micron Spitzer/IRAC Galactic Center Survey Point Sources with Chandra X-Ray Point Sources in the Central 40x40 Parsecs, we encourage you to share that experience with our LandOfFree.com community. Your opinion is very important and Comparison of 3.6 - 8.0 Micron Spitzer/IRAC Galactic Center Survey Point Sources with Chandra X-Ray Point Sources in the Central 40x40 Parsecs will most certainly appreciate the feedback.
Profile ID: LFWR-SCP-O-265890