Comparison between steady-state and dynamic I-V measurements from a single-cell thermionic fuel element

Statistics – Applications

Scientific paper

Rate now

  [ 0.00 ] – not rated yet Voters 0   Comments 0

Details

Spaceborne And Space Research Instruments, Apparatus, And Components, Fuel Elements, Preparation, Reloading, And Reprocessing, Thermionic Conversion

Scientific paper

A comparison between steady-state and dynamic I-V measurements from a single-cell thermionic fuel element (TFE) is made. The single-cell TFE used in this study is the prototype for the 40 kWe space nuclear power system that is similar to the 6 kWe TOPAZ-II. The steady-state I-V measurements influence the emitter temperature due to electron cooling. Therefore, to eliminate the steady-state I-V measurement influence on the TFE and provide a better understanding of the behavior of the thermionic energy converter and TFE characteristics, dynamic I-V measurements are made. The dynamic I-V measurements are made at various input power levels, cesium pressures, collector temperatures, and steady-state current levels. From these measurements, it is shown that the dynamic I-V's do not change the TFE characteristics at a given operating point. Also, the evaluation of the collector work function from the dynamic I-V measurements shows that the collector optimization is not due to a minimum in the collector work function but due to an emission optimization. Since the dynamic I-V measurements do not influence the TFE characteristics, it is believed that these measurements can be done at a system level to understand the influence of TFE placement in the reactor as a function of the core thermal distribution.

No associations

LandOfFree

Say what you really think

Search LandOfFree.com for scientists and scientific papers. Rate them and share your experience with other people.

Rating

Comparison between steady-state and dynamic I-V measurements from a single-cell thermionic fuel element does not yet have a rating. At this time, there are no reviews or comments for this scientific paper.

If you have personal experience with Comparison between steady-state and dynamic I-V measurements from a single-cell thermionic fuel element, we encourage you to share that experience with our LandOfFree.com community. Your opinion is very important and Comparison between steady-state and dynamic I-V measurements from a single-cell thermionic fuel element will most certainly appreciate the feedback.

Rate now

     

Profile ID: LFWR-SCP-O-1784775

  Search
All data on this website is collected from public sources. Our data reflects the most accurate information available at the time of publication.