Combined radiation damage, annealing, and ageing studies of InGaAsP/InP 1310nm lasers for the CMS tracker optical links

Computer Science

Scientific paper

Rate now

  [ 0.00 ] – not rated yet Voters 0   Comments 0

Details

2

Scientific paper

A summary is presented of the combined effects of radiation damage, accelerated annealing and accelerated ageing in 1310nm InGaAsP/InP multi-quantum-well lasers, the type chosen for use in the CMS Tracker optical links. The radiation damage effects are compared for a variety of radiation sources: 60Co-gamma, 0.8MeV (average energy) neutrons, 20MeV (average energy) neutrons and 300MeV/c pions that represent important parts of the spectrum of particles that will be encountered in the CMS Tracker. The relative damage factors of the various sources are calculated by comparing the laser threshold current increase due to radiation damage giving ~0 : 0.12 : 0.53 : 1 for 60Co-gamma, ~0.8MeV neutrons, ~20MeV neutrons with respect to 300MeV/c pions. The effects of bias current and temperature on the annealing were measured and, in all cases, the annealing is proportional to log(annealing time). A bias current of 60mA increases the annealing, in terms of the time taken to anneal a given amount, by a factor of 10 relative to 0mA. The annealing rate is also accelerated by heating the irradiated lasers and recovery occurs ~10 times faster at 60°C than at 20°C. The long-term ageing properties of irradiated lasers were also measured in an accelerated test carried out at 80°C, for 2500 hours, at a bias current of 60mA. No wearout-related degradation was observed in any of the devices. The combined results of these studies have been used to estimate the long-term damage expected for this type of laser operating inside the CMS Tracker. In the worst case of a laser operating at a distance of 22cm from the beam-axis in the forward region of the Tracker, the maximum threshold increase will be ~6mA over the first 10 years of LHC running.

No associations

LandOfFree

Say what you really think

Search LandOfFree.com for scientists and scientific papers. Rate them and share your experience with other people.

Rating

Combined radiation damage, annealing, and ageing studies of InGaAsP/InP 1310nm lasers for the CMS tracker optical links does not yet have a rating. At this time, there are no reviews or comments for this scientific paper.

If you have personal experience with Combined radiation damage, annealing, and ageing studies of InGaAsP/InP 1310nm lasers for the CMS tracker optical links, we encourage you to share that experience with our LandOfFree.com community. Your opinion is very important and Combined radiation damage, annealing, and ageing studies of InGaAsP/InP 1310nm lasers for the CMS tracker optical links will most certainly appreciate the feedback.

Rate now

     

Profile ID: LFWR-SCP-O-1128933

  Search
All data on this website is collected from public sources. Our data reflects the most accurate information available at the time of publication.