Combined calibration and nonuniformity correction of a sensor for improved projector nonuniformity correction

Computer Science

Scientific paper

Rate now

  [ 0.00 ] – not rated yet Voters 0   Comments 0

Details

Scientific paper

One proven technique for nonuniformity correction (NUC) of a resistor array infrared scene projector requires careful measurement of the output-versus-input response for every emitter in a large array. In previous papers, we have discussed methods and results for accomplishing the projector NUC. Two difficulties that may limit the NUC results are residual nonuniformity in the calibration sensor, and nonlinearity in the calibration sensor's response to scene radiance. These effects introduce errors in the measurement of the projector elements' output, which lead to residual nonuniformity. In this paper we describe a recent effort to mitigate both of these problems using a procedure that combines sensor nonuniformity correction and sensor calibration, detector by detector, so that these problems do not contaminate the projector NUC. By measuring a set of blackbody flood-field images at a dozen or so different temperatures, the individual detector output-versus-input radiance responses can be measured. Similar to the projector NUC, we use a curve-fitting routine to model the response of each detector. Using this set of response curves, a post-processing algorithm is used to correct and calibrate the images measured by the sensor. We have used this approach to reduce several sensor error sources by a factor of 10 to 100. The resulting processing is used to correct and calibrate all of the sensor images used to perform the projector NUC, as one step in the projector NUC. The procedure appears to be useful for any application where sensor nonuniformity or response nonlinearities are significant.

No associations

LandOfFree

Say what you really think

Search LandOfFree.com for scientists and scientific papers. Rate them and share your experience with other people.

Rating

Combined calibration and nonuniformity correction of a sensor for improved projector nonuniformity correction does not yet have a rating. At this time, there are no reviews or comments for this scientific paper.

If you have personal experience with Combined calibration and nonuniformity correction of a sensor for improved projector nonuniformity correction, we encourage you to share that experience with our LandOfFree.com community. Your opinion is very important and Combined calibration and nonuniformity correction of a sensor for improved projector nonuniformity correction will most certainly appreciate the feedback.

Rate now

     

Profile ID: LFWR-SCP-O-1189900

  Search
All data on this website is collected from public sources. Our data reflects the most accurate information available at the time of publication.