CO(1-0) imaging of M51 with CARMA and NRO45

Astronomy and Astrophysics – Astrophysics – Instrumentation and Methods for Astrophysics

Scientific paper

Rate now

  [ 0.00 ] – not rated yet Voters 0   Comments 0

Details

24 pages, 11 figures. Accepted for publication in ApJS

Scientific paper

We report the CO(J=1-0) observations of M51 using both the Combined Array for Research in Millimeter Astronomy (CARMA) and the Nobeyama 45m telescope (NRO45). We describe a procedure for the combination of interferometer and single-dish data. In particular, we discuss (1) the joint imaging and deconvolution of heterogeneous data, (2) the weighting scheme based on the root-mean-square (RMS) noise in the maps, (3) the sensitivity and uv-coverage requirements, and (4) the flux recovery of a combined map. We generate visibilities from the single-dish map and calculate the noise of each visibility based on the RMS noise. Our weighting scheme, though it is applied to discrete visibilities in this paper, is applicable to grids in uv-space, and this scheme may advance in future software development. For a realistic amount of observing time, the sensitivities of the NRO45 and CARMA visibility data sets are best matched by using the single dish baselines only up to 4-6 kilo-lambda (about 1/4-1/3 of the dish diameter). The synthesized beam size is determined to conserve the flux between synthesized beam and convolution beam. The superior uv-coverage provided by the combination of CARMA long baseline data with 15 antennas and NRO45 short spacing data results in the high image fidelity, which is evidenced by the excellent overlap between even the faint CO emission and dust lanes in an optical HST image and PAH emission in an Spitzer 8 micron image.

No associations

LandOfFree

Say what you really think

Search LandOfFree.com for scientists and scientific papers. Rate them and share your experience with other people.

Rating

CO(1-0) imaging of M51 with CARMA and NRO45 does not yet have a rating. At this time, there are no reviews or comments for this scientific paper.

If you have personal experience with CO(1-0) imaging of M51 with CARMA and NRO45, we encourage you to share that experience with our LandOfFree.com community. Your opinion is very important and CO(1-0) imaging of M51 with CARMA and NRO45 will most certainly appreciate the feedback.

Rate now

     

Profile ID: LFWR-SCP-O-378387

  Search
All data on this website is collected from public sources. Our data reflects the most accurate information available at the time of publication.