Statistics – Applications
Scientific paper
Mar 2008
adsabs.harvard.edu/cgi-bin/nph-data_query?bibcode=2008spie.6624e..44g&link_type=abstract
International Symposium on Photoelectronic Detection and Imaging 2007: Optoelectronic System Design, Manufacturing, and Testing.
Statistics
Applications
Scientific paper
With the developments of science of art, there are more and more demands on the high resolution control of position of object to be controlled, such as lathe, product line, elements in the optical resonant cavity, telescope, and so on. As one device with high resolution, the optical scale has more and more utility within the industrial and civil applications. With one optical scale and small DC servo motor, one closed loop high resolution position control system is constructed. This apparatus is used to control the position of the elements of optical system. The optical scale is attached on the object or reference guide way. The object position is sampled by a readhead of non-contact optical encoder. Control system processes the position information and control the position of object through the motion control of servo DC motor. The DC motor is controlled by one controller which is connected to an industrial computer. And the micro frictionless slide table does support the smooth motion of object to be controlled. The control algorithm of system is PID (Proportional-Integral-Differential) methods. The PID control methods have well ROBUST. The needed data to control are position, velocity and acceleration of the object. These three parameters correspond to the PID characters respectively. After the accomplishments of hardware, GUI (Graphical user interface), that is, the software of control system is also programmed. The whole system is assembled by specialized worker. Through calibration experiments, the coefficients of PID are obtained respectively. And then the precision of position control of the system is about 0.1μm.
Fan Guo-bin
Ge Cheng-liang
He Zhong-wu
Hu Xiao-yang
Huang Zhi-wei
No associations
LandOfFree
Closed loop high precision position control system with optical scale does not yet have a rating. At this time, there are no reviews or comments for this scientific paper.
If you have personal experience with Closed loop high precision position control system with optical scale, we encourage you to share that experience with our LandOfFree.com community. Your opinion is very important and Closed loop high precision position control system with optical scale will most certainly appreciate the feedback.
Profile ID: LFWR-SCP-O-882902