Charge-Coupled Devices, Laser Beams, Laser Variables Measurement, Beam Characteristics: Profile, Intensity, And Power, Spatial Pattern Formation, Field Effect Devices

Scientific paper

A position sensitive device (PSD) is frequently used in laser beam deviation measurement. However, it lacks the capability to retrieve the power distribution information of a laser beam. A charge-coupled device (CCD) gives much more information of a laser beam than a PSD. The requirement of a multifunctional sensor makes the replacement of a PSD with a CCD in measuring laser beam deviation to be a reasonable topic. In this paper a performance comparison between a PSD and a CCD combined with a centroid algorithm are discussed with special attention paid to the CCD-based system. According to the operating principle of the CCD-based system, several experiments were carried out to evaluate five factors of the CCD-based system: image window size, number of processed images, threshold, binning, and saturation. By applying the optimized parameters, several experiments were made to compare the CCD-based system with the state-of-the-art PSD-based system in terms of two performance indicators, namely resolution and speed. It is shown that, by applying the optimized parameters, the performance of a CCD-based system is comparable to that of a PSD-based system in measuring laser beam deviation.

No associations

LandOfFree

Say what you really think

Search LandOfFree.com for scientists and scientific papers. Rate them and share your experience with other people.

Rating

Charge-coupled devices combined with centroid algorithm for laser beam deviation measurements compared to a position-sensitive device does not yet have a rating. At this time, there are no reviews or comments for this scientific paper.

If you have personal experience with Charge-coupled devices combined with centroid algorithm for laser beam deviation measurements compared to a position-sensitive device, we encourage you to share that experience with our LandOfFree.com community. Your opinion is very important and Charge-coupled devices combined with centroid algorithm for laser beam deviation measurements compared to a position-sensitive device will most certainly appreciate the feedback.

Rate now

     

Profile ID: LFWR-SCP-O-1401819

  Search
All data on this website is collected from public sources. Our data reflects the most accurate information available at the time of publication.