Characterization of an x-ray framing camera utilizing a charge coupled device or film as recording media

Computer Science – Performance

Scientific paper

Rate now

  [ 0.00 ] – not rated yet Voters 0   Comments 0

Details

5

X-Ray And Gamma-Ray Measurements, X- And Gamma-Ray Sources, Mirrors, Gratings, And Detectors, Photodetectors, Plasma Production And Heating By Laser Beams, Fueling, Heating And Ignition

Scientific paper

A compact charge coupled device (CCD) camera system has been designed and characterized for use in the six inch manipulator (SIM) at the Nova laser facility. The camera system has been designed to directly replace the 35 mm film packages currently used in SIM-based x-ray imaging diagnostics. The unit's electronic package has been constructed for small size and high thermal conductivity which reduces the overall camera size and improves its performance when operated within the vacuum environment of the Nova target chamber. Measurements of the x-ray imager's contrast transfer function (CTF) were made under a variety of operating conditions on a static x-ray Manson source using both the CCD and Kodak T-Max 3200 film as recording media. The CTF data were converted to an equivalent modulation transfer function (MTF). The MTF plots show that the microchannel plate has a uniform response within our measurement accuracy along its strips. In a direction normal to the strip, however, the MTF is reduced due to the slant angle of the pores in the MCP. The measurements show that the CCD camera has a lower MTF response than T-MAX film for all spatial frequencies and configurations measured. However, data obtained from the film exhibited reciprocity failure and border effects that are not observed in the CCD data. Measurements indicate that the signal-to-noise ratio for the CCD data is four to six times larger than that obtained with film and higher photon flux levels were recorded. The CCD-based diagnostic offers immediate access to the data, improved dynamic range, and reduced turnaround time, while eliminating the need for film development, digitization, equipment, and personnel.

No associations

LandOfFree

Say what you really think

Search LandOfFree.com for scientists and scientific papers. Rate them and share your experience with other people.

Rating

Characterization of an x-ray framing camera utilizing a charge coupled device or film as recording media does not yet have a rating. At this time, there are no reviews or comments for this scientific paper.

If you have personal experience with Characterization of an x-ray framing camera utilizing a charge coupled device or film as recording media, we encourage you to share that experience with our LandOfFree.com community. Your opinion is very important and Characterization of an x-ray framing camera utilizing a charge coupled device or film as recording media will most certainly appreciate the feedback.

Rate now

     

Profile ID: LFWR-SCP-O-765507

  Search
All data on this website is collected from public sources. Our data reflects the most accurate information available at the time of publication.