Calorimetric low temperature detectors for mass identification of heavy ions

Computer Science – Performance

Scientific paper

Rate now

  [ 0.00 ] – not rated yet Voters 0   Comments 0

Details

1

Calorimeters, Isotope Separation And Enrichment

Scientific paper

The energy sensitive detection of heavy ions with calorimetric low temperature detectors (CLTDs) is investigated for the energy range E=0.1-1 MeV/u, commonly used for accelerator mass spectrometry (AMS). Such measurements complement earlier investigations [1, 2] at higher energies (E=5-300 MeV/u) where an energy resolution of ΔE/E=1-2×10-3 was obtained for various ion species. The detectors used consist of sapphire absorbers and superconducting transition edge thermometers operated at T~1.5 K. They were irradiated with various heavy ion beams (13C, 197Au, 238U) provided by the VERA tandem accelerator in Vienna, Austria. An energy resolution of ΔE/E=5-6×10-3 has been obtained even for heaviest ions like 197Au and 238U at E=0.1-0.3 MeV/u, thereby exceeding the resolution of conventional semiconductor detectors in this energy range by at least one order of magnitude. In addition, no evidence for pulse height defects has been observed. With the achieved performance, the present CLTDs bear a large potential for applications in various fields of heavy ion research. Of special interest is isotope mass identification via combined energy and time-of-flight (TOF) measurement. In present test measurements, including a standard TOF spectrometer, a clear separation of the isotopes 206Pb and 208Pb at E~0.1 MeV/u has been obtained. Such a detection scheme may in future provide substantial background suppression for AMS measurements. .

No associations

LandOfFree

Say what you really think

Search LandOfFree.com for scientists and scientific papers. Rate them and share your experience with other people.

Rating

Calorimetric low temperature detectors for mass identification of heavy ions does not yet have a rating. At this time, there are no reviews or comments for this scientific paper.

If you have personal experience with Calorimetric low temperature detectors for mass identification of heavy ions, we encourage you to share that experience with our LandOfFree.com community. Your opinion is very important and Calorimetric low temperature detectors for mass identification of heavy ions will most certainly appreciate the feedback.

Rate now

     

Profile ID: LFWR-SCP-O-1791481

  Search
All data on this website is collected from public sources. Our data reflects the most accurate information available at the time of publication.