Calibration Using Matrix Completion with Application to Ultrasound Tomography

Computer Science – Learning

Scientific paper

Rate now

  [ 0.00 ] – not rated yet Voters 0   Comments 0

Details

submitted to IEEE Transaction on Signal Processing

Scientific paper

We study the calibration process in circular ultrasound tomography devices where the sensor positions deviate from the circumference of a perfect circle. This problem arises in a variety of applications in signal processing ranging from breast imaging to sensor network localization. We introduce a novel method of calibration/localization based on the time-of-flight (ToF) measurements between sensors when the enclosed medium is homogeneous. In the presence of all the pairwise ToFs, one can easily estimate the sensor positions using multi-dimensional scaling (MDS) method. In practice however, due to the transitional behaviour of the sensors and the beam form of the transducers, the ToF measurements for close-by sensors are unavailable. Further, random malfunctioning of the sensors leads to random missing ToF measurements. On top of the missing entries, in practice an unknown time delay is also added to the measurements. In this work, we incorporate the fact that a matrix defined from all the ToF measurements is of rank at most four. In order to estimate the missing ToFs, we apply a state-of-the-art low-rank matrix completion algorithm, OPTSPACE . To find the correct positions of the sensors (our ultimate goal) we then apply MDS. We show analytic bounds on the overall error of the whole process in the presence of noise and hence deduce its robustness. Finally, we confirm the functionality of our method in practice by simulations mimicking the measurements of a circular ultrasound tomography device.

No associations

LandOfFree

Say what you really think

Search LandOfFree.com for scientists and scientific papers. Rate them and share your experience with other people.

Rating

Calibration Using Matrix Completion with Application to Ultrasound Tomography does not yet have a rating. At this time, there are no reviews or comments for this scientific paper.

If you have personal experience with Calibration Using Matrix Completion with Application to Ultrasound Tomography, we encourage you to share that experience with our LandOfFree.com community. Your opinion is very important and Calibration Using Matrix Completion with Application to Ultrasound Tomography will most certainly appreciate the feedback.

Rate now

     

Profile ID: LFWR-SCP-O-582107

  Search
All data on this website is collected from public sources. Our data reflects the most accurate information available at the time of publication.