Calibration systems and methods for the ANTARES neutrino telescope

Astronomy and Astrophysics – Astrophysics

Scientific paper

Rate now

  [ 0.00 ] – not rated yet Voters 0   Comments 0

Details

4 pages, 3 figures, to appear in the proceedings of 30th International Cosmic Ray Conference (ICRC 2007), Merida, Yucatan, Mex

Scientific paper

The ANTARES neutrino telescope is currently being constructed in the Mediterranean Sea. The complete detector will consist of 12 strings, supplemented by an additional instrumentation line. Nine strings are at present deployed of which five are already connected to the shore and operating. Each string is equipped with 75 Optical Modules (OMs) housing the photomultipliers to detect the Cherenkov light induced by the charged particles produced in neutrino reactions. An accurate measurement of the Cherenkov photon arrival times as well as the positions and orientations of the OMs is required for a precise reconstruction of the direction of the detected neutrinos. For this purpose the ANTARES detector is provided with several system s to facilitate the calibration of the detector. The time calibration is performed using light pulses emitted from LED and laser devices. The positioning is done via acoustic triangulation using hydrophones. Additionally, local tilt angles and the orientations of the modules are measured with a set of tiltmeters and compasses. In this paper, it is demonstrated that the ANTARES time and alignment calibration systems operate successfully in situ. In particular, it is shown that the ANTARES read-out electronics is capable of reaching a sub-nanosecond time resolution.

No associations

LandOfFree

Say what you really think

Search LandOfFree.com for scientists and scientific papers. Rate them and share your experience with other people.

Rating

Calibration systems and methods for the ANTARES neutrino telescope does not yet have a rating. At this time, there are no reviews or comments for this scientific paper.

If you have personal experience with Calibration systems and methods for the ANTARES neutrino telescope, we encourage you to share that experience with our LandOfFree.com community. Your opinion is very important and Calibration systems and methods for the ANTARES neutrino telescope will most certainly appreciate the feedback.

Rate now

     

Profile ID: LFWR-SCP-O-531617

  Search
All data on this website is collected from public sources. Our data reflects the most accurate information available at the time of publication.