Calibration strategies for instrumental polarization at the 10-5 level

Astronomy and Astrophysics – Astronomy

Scientific paper

Rate now

  [ 0.00 ] – not rated yet Voters 0   Comments 0

Details

Scientific paper

Many current instrumental developments for both solar and nighttime telescopes are directed at measuring the polarization state of the incoming light in addition to determining its spatial, temporal and/or spectral properties. Such polarimeters need to be sensitive down to a polarization degree of the order of 10-5 e.g. to employ the full range of diagnostics to accurately measure solar magnetic fields or to enable direct imaging of extrasolar planetary systems. At the low polarization degree of these observations, it is crucial to accurately know the polarization properties of the instrument itself. Since instrumental polarization is inevitable for any telescopic configuration with oblique reflections or refractions, it is always necessary to cope with it by means of calibration in combination with (limited) forward modeling. I present general strategies based on discrete Fourier analysis for the calibration of instrumental polarization to enable astronomical (spectro-)polarimetry at the 10-5 level. The technique only assumes the presence of a freely rotatable polarizer and (quarter) wave plate to create known input polarization states. The Fourier components of the observed output polarization contain information about the full instrumental polarization, as well as about non-ideal effects in the calibration elements, polarized input to the calibration unit and non-linear response of the detector.

No associations

LandOfFree

Say what you really think

Search LandOfFree.com for scientists and scientific papers. Rate them and share your experience with other people.

Rating

Calibration strategies for instrumental polarization at the 10-5 level does not yet have a rating. At this time, there are no reviews or comments for this scientific paper.

If you have personal experience with Calibration strategies for instrumental polarization at the 10-5 level, we encourage you to share that experience with our LandOfFree.com community. Your opinion is very important and Calibration strategies for instrumental polarization at the 10-5 level will most certainly appreciate the feedback.

Rate now

     

Profile ID: LFWR-SCP-O-1624890

  Search
All data on this website is collected from public sources. Our data reflects the most accurate information available at the time of publication.