Calibration of temperature and relative humidity sensors for use on the VLT-Interferometer

Computer Science

Scientific paper

Rate now

  [ 0.00 ] – not rated yet Voters 0   Comments 0

Details

2

Scientific paper

Knowledge of the dispersion due to (humid) air in the light path of the Very Large Telescope Interferometer (VLTI) is crucial to obtaining good science data from MIDI, PRIMA and GENIE. To calculate the refraction due to air at infra red wavelengths in the ducts and delay line tunnel, the temperature and humidity has to be monitored during observations. To accomplish these measurements an easy to use and reliable system was assembled, based on commercially available components. In-house calibration of four humidity and temperature sensors of the system was done in Leiden. A test and calibration program was carried out to make sure that they work reliably and accurately and to determine the sensor characteristics. For this purpose a calibration box was designed which isolates the sensors from the environment so that there is no exchange of air with the outside environment. Using constant humidity salt solutions, the humidity in the box can be controlled. This allows the calibrations to be carried out for typical values of relative humidity and temperature at Cerro Paranal. Calibration of the sensors includes: 1. Reducing the systematic relative humidity differences between the sensors to less than 0.1 % and 2. Reducing the systematic temperature differences between the sensors to less than 0.01 K. In this paper we will present the outcome of the calibrations and the future of the sensors at Paranal.

No associations

LandOfFree

Say what you really think

Search LandOfFree.com for scientists and scientific papers. Rate them and share your experience with other people.

Rating

Calibration of temperature and relative humidity sensors for use on the VLT-Interferometer does not yet have a rating. At this time, there are no reviews or comments for this scientific paper.

If you have personal experience with Calibration of temperature and relative humidity sensors for use on the VLT-Interferometer, we encourage you to share that experience with our LandOfFree.com community. Your opinion is very important and Calibration of temperature and relative humidity sensors for use on the VLT-Interferometer will most certainly appreciate the feedback.

Rate now

     

Profile ID: LFWR-SCP-O-1810494

  Search
All data on this website is collected from public sources. Our data reflects the most accurate information available at the time of publication.