Calibrating IR optical densities for the Gemini Planet Imager extreme adaptive optics coronagraph apodizers

Astronomy and Astrophysics – Astronomy

Scientific paper

Rate now

  [ 0.00 ] – not rated yet Voters 0   Comments 0

Details

4

Scientific paper

High contrast imaging sometimes uses apodized masks in coronagraphs to suppress diffracted starlight from a bright source in order to observe its environs. Continuously graded opacity material and metallic half-tone dots are two possible apodizers fabrication techniques. In the latter approach if dot sizes are comparable to the wavelength of the light, surface plasmon effects can complicate the optical density (OD) vs. superficial dot density relation. OD can also be a complicated function of wavelength. We measured half-tone microdot screens' and continuous materials' transmissions. Our set-up replicated the f/ 64 optical configuration of the Gemini Planet Imager's Apodized Pupil Lyot Coronagraph pupil plane, where we plan to place our pupil plane masks. Our half-tone samples were fabricated with 2, 5, and 10 micron dot sizes, our continuous greyscale was High Energy Electron Beam Sensitive (HEBS) glass (Canyon Materials Inc.). We present optical density (OD) vs. wavelength curves for our half-tone and continuous greyscale samples 1.1 - 2.5 μm wavelength range. Direct measurements of the beam intensity in the far field using a Fourier Transform Infrared Spectrograph on Beamline U4IR at Brookhaven National Laboratory's National Synchrotron Light Source (NSLS) provided transmission spectra of test patches and apodizers. We report the on-axis IR transmission spectra through screens composed of metallic dots that are comparable in size with the wavelength of the light used, over a range of optical densities. We also measured departures from simple theory describing the array of satellite spots created by thin periodic grids in the pupil of the system. Such spots are used for photometry and astrometry in coronagraphic situations. Our results pertain to both ground and space based coronagraphs that use spatially variable attenuation, typically in focal plane or pupil plane masks.

No associations

LandOfFree

Say what you really think

Search LandOfFree.com for scientists and scientific papers. Rate them and share your experience with other people.

Rating

Calibrating IR optical densities for the Gemini Planet Imager extreme adaptive optics coronagraph apodizers does not yet have a rating. At this time, there are no reviews or comments for this scientific paper.

If you have personal experience with Calibrating IR optical densities for the Gemini Planet Imager extreme adaptive optics coronagraph apodizers, we encourage you to share that experience with our LandOfFree.com community. Your opinion is very important and Calibrating IR optical densities for the Gemini Planet Imager extreme adaptive optics coronagraph apodizers will most certainly appreciate the feedback.

Rate now

     

Profile ID: LFWR-SCP-O-1303963

  Search
All data on this website is collected from public sources. Our data reflects the most accurate information available at the time of publication.