C IV and other Metal Absorption Line Systems in 18 z=4 Quasars

Astronomy and Astrophysics – Astronomy

Scientific paper

Rate now

  [ 0.00 ] – not rated yet Voters 0   Comments 0

Details

18

Galaxies: Abundances, Galaxies: Evolution, Galaxies: Quasars: Absorption Lines

Scientific paper

We present a modest survey of quasar metal line absorption systems at redshifts 2.3-4.5. Relatively high signal-to-noise ratio (~25 pixel-1) spectra of 18 quasars at 2 Å FWHM resolution show many absorption systems with strong metal lines in the region redward of the Lyα emission lines. We conducted a systematic search and found 55 C IV doublets, 19 Si IV doublets, three Mg II doublets, and seven N V doublets. The present data alone hint that the number of C IV absorption doublets per unit redshift, N(z), decreases with increasing redshift for 2.30.3 Å are approximately 55% of all C IV systems with W>0.15 Å, but by z~=4 that percentage is less than 37%. Similar conclusions were reached by Sargent, Boksenberg, & Steidel and by Steidel, primarily at lower redshifts. However, we measure approximately twice the density of C IV systems at 2.30.15 Å that was reported by Steidel. The probability that our sample and previous samples come from the same distribution is only ~2%. But this could be a statistical accident because it is an a posteriori comparison. We believe that the systems that we report are real, and we have no other explanation for this difference. For Si IV absorption lines, there is a 1 σ hint of evolution with the same sense. In contrast, Lyα and Mg II systems are known to show evolution of the opposite sense with more absorbers at larger redshifts. The physical cause of this difference may be a mixture of ionization and chemical evolution effects.

No associations

LandOfFree

Say what you really think

Search LandOfFree.com for scientists and scientific papers. Rate them and share your experience with other people.

Rating

C IV and other Metal Absorption Line Systems in 18 z=4 Quasars does not yet have a rating. At this time, there are no reviews or comments for this scientific paper.

If you have personal experience with C IV and other Metal Absorption Line Systems in 18 z=4 Quasars, we encourage you to share that experience with our LandOfFree.com community. Your opinion is very important and C IV and other Metal Absorption Line Systems in 18 z=4 Quasars will most certainly appreciate the feedback.

Rate now

     

Profile ID: LFWR-SCP-O-1533940

  Search
All data on this website is collected from public sources. Our data reflects the most accurate information available at the time of publication.