Superconducting YBCO microbridge has been proven with high sensitivity and fast response speed. We have prepared successfully the High Tc superconducting IR detectors of this composition. When the temperature of blackbody is 500K the performance of detector is: D* equals 5.06 X 10(superscript 10) cmHz(superscript 1/z)W(superscript -1); NEP equals 2.8 X 10(superscript -14)WHz(superscript -1/2); R equals 8.87 X 10(superscript 4)VW(superscript -1) and this performance can be held stable in two years. Using the detector we have done experiment at bolometric response from 300K to 600K and spectral response from 1 micrometers to 1224 micrometers . Experiment results show that the detector is nearing practical use and is the best detector for wide band.
Li Dan
Li Guo Zhen
Zhou Jianxun
No associations
LandOfFree
Bolometric and spectral response of a superconducting YBCO microbridge infrared detector does not yet have a rating. At this time, there are no reviews or comments for this scientific paper.
If you have personal experience with Bolometric and spectral response of a superconducting YBCO microbridge infrared detector, we encourage you to share that experience with our LandOfFree.com community. Your opinion is very important and Bolometric and spectral response of a superconducting YBCO microbridge infrared detector will most certainly appreciate the feedback.