Biological dosimetry after H2O2/L-histidine treatment

Mathematics – Logic

Scientific paper

Rate now

  [ 0.00 ] – not rated yet Voters 0   Comments 0

Details

Scientific paper

In biological dosimetry after radiation or chemical exposure, it has been well established to estimate exposure doses from the relative rate of aberrant chromosomes, especially dicentric chromosomes in a given number of cells. For this purpose, dose-efficiency curves depending on laboratory parameters (e.g. preparation technique, analysis procedure etc.) have to be measured under standard conditions. For statistical reasons, a high number of chromosomes or cells, respectively, has to be evaluated. For a Chinese hamster cell line (CO60) as a typical model system in mutation research, a dose efficiency relation after H2O2/L-histidine treatment of the cells was determined using the Heidelberg slit-scan flow fluorometer. This technique has the advantage that several thousand chromosomes can be automatically analyzed in a very short time. As expected, for low doses of H2O2/L-histidine exposure, a nearly linear dependence of the relative number of dicentric chromosomes to the concentration of H2O2 was obtained. In order to correlate the relative number of dicentric chromosomes to the relative number of double strand breaks, the cells were analyzed by the technique of the neutral comet assay. The dose dependent `tail moment' obtained from the comet assay also showed a linear behavior. This confirmed the results obtained by slit-scan flow fluorometry. Furthermore, the linear dependence of the dose efficiency curve was well compatible to results obtained by visual counting by means of a fluorescence microscope. In this case chromosome 1 of the Chinese hamster cell line DON was specifically labelled by fluorescence in situ hybridization.

No associations

LandOfFree

Say what you really think

Search LandOfFree.com for scientists and scientific papers. Rate them and share your experience with other people.

Rating

Biological dosimetry after H2O2/L-histidine treatment does not yet have a rating. At this time, there are no reviews or comments for this scientific paper.

If you have personal experience with Biological dosimetry after H2O2/L-histidine treatment, we encourage you to share that experience with our LandOfFree.com community. Your opinion is very important and Biological dosimetry after H2O2/L-histidine treatment will most certainly appreciate the feedback.

Rate now

     

Profile ID: LFWR-SCP-O-1045458

  Search
All data on this website is collected from public sources. Our data reflects the most accurate information available at the time of publication.