Biases on initial mass function determinations. III. Cluster masses derived from unresolved photometry

Astronomy and Astrophysics – Astrophysics – Instrumentation and Methods for Astrophysics

Scientific paper

Rate now

  [ 0.00 ] – not rated yet Voters 0   Comments 0

Details

Acepted for publication in ApJ, 47 pages, 8 figues

Scientific paper

10.1088/0004-637X/699/2/1938

It is currently common to use spatially unresolved multi-filter broad-band photometry to determine the masses of individual stellar clusters (and hence the cluster mass function, CMF). I analyze the stochastic effects introduced by the sampling of the stellar initial mass function (SIMF) in the derivation of the individual masses and the CMF and I establish that such effects are the largest contributor to the observational uncertainties. An analytical solution, valid in the limit where uncertainties are small, is provided to establish the range of cluster masses over which the CMF slope can be obtained with a given accuracy. The validity of the analytical solution is extended to higher mass uncertainties using Monte Carlo simulations and the Gamma approximation. The value of the Poisson mass is calculated for a large range of ages and a variety of filters for solar-metallicity clusters measured with single-filter photometry. A method that uses the code CHORIZOS is presented to simultaneously derive masses, ages, and extinctions. The classical method of using unweighted UBV photometry to simultaneously establish ages and extinctions of stellar clusters is found to be unreliable for clusters older than approx. 30 Ma, even for relatively large cluster masses. On the other hand, augmenting the filter set to include longer-wavelength filters and using weights for each filter increases the range of masses and ages that can be accurately measured with unresolved photometry. Nevertheless, a relatively large range of masses and ages is found to be dominated by SIMF sampling effects that render the observed masses useless, even when using UBVRIJHK photometry. A revision of some literature results affected by these effects is presented and possible solutions for future observations and analyses are suggested.

No associations

LandOfFree

Say what you really think

Search LandOfFree.com for scientists and scientific papers. Rate them and share your experience with other people.

Rating

Biases on initial mass function determinations. III. Cluster masses derived from unresolved photometry does not yet have a rating. At this time, there are no reviews or comments for this scientific paper.

If you have personal experience with Biases on initial mass function determinations. III. Cluster masses derived from unresolved photometry, we encourage you to share that experience with our LandOfFree.com community. Your opinion is very important and Biases on initial mass function determinations. III. Cluster masses derived from unresolved photometry will most certainly appreciate the feedback.

Rate now

     

Profile ID: LFWR-SCP-O-371321

  Search
All data on this website is collected from public sources. Our data reflects the most accurate information available at the time of publication.