Background Studies of a Position Sensitive CdZnTe X-ray Detector at Balloon Altitudes

Astronomy and Astrophysics – Astronomy

Scientific paper

Rate now

  [ 0.00 ] – not rated yet Voters 0   Comments 0

Details

Scientific paper

Cadmium Zinc Telluride (CZT) is a room temperature semiconductor detector well suited for high energy X-ray astronomy. As part of the High Energy X-ray Imaging Spectrometer (HEXIS) development, we flew a position sensitive CZT detector on two balloon flights using seven shielding schemes to study the background properties of the CZT detector. Passive, active and hybrid passive-active shields were used on the cross-strip detector as well as on a standard planar CZT flown along side the cross-strip CZT for comparison. The cross-strip detector utilizes our recently developed, novel electrode configuration that improves interaction localization and depth of interaction (DOI) determination. During the flight, shield pulse heights were telemetered along with event data allowing us to conduct detailed studies of shield rejection effects. Preliminary results have been presented on the effectiveness of shielding and background reduction techniques that employ the DOI, as indicated by the ratio of cathode to anode pulse height (Slavis, et. al., SPIE Proc., 3445, 169, 1998, and Slavis, et. al., AAS #193, #66.05, 1999). Preliminary analysis indicates the 40-80 keV background is 4x10(-4) (cts)/(cm(2-s-keV)) for the cross-strip CZT without applying rejection techniques other than an active-shield energy deposition veto. We present here results incorporating more sophisticated background rejection techniques such as refinements to the preliminary DOI cut, multiple-site signatures and a more detailed investigation of the dependence of shield energy deposition on background rejection. We will also present upper limits on CZT activation. This is possible because the long duration at float in 1998 permitted cycling through the shield configurations for run times separated by at least 8 hours. Based on our preliminary analysis, we are confident that CZT detectors will be desirable for future low background, hard X-ray astronomy missions.

No associations

LandOfFree

Say what you really think

Search LandOfFree.com for scientists and scientific papers. Rate them and share your experience with other people.

Rating

Background Studies of a Position Sensitive CdZnTe X-ray Detector at Balloon Altitudes does not yet have a rating. At this time, there are no reviews or comments for this scientific paper.

If you have personal experience with Background Studies of a Position Sensitive CdZnTe X-ray Detector at Balloon Altitudes, we encourage you to share that experience with our LandOfFree.com community. Your opinion is very important and Background Studies of a Position Sensitive CdZnTe X-ray Detector at Balloon Altitudes will most certainly appreciate the feedback.

Rate now

     

Profile ID: LFWR-SCP-O-889999

  Search
All data on this website is collected from public sources. Our data reflects the most accurate information available at the time of publication.