9 pages, 7 figures (in 8 files). Presented at SPIE, Aug. 2002. To appear in Proc. SPIE, volume 4851. Errors in references and

Scientific paper

10.1117/12.461537

We report detector characteristics and background measurements from two prototype imaging CZT detectors flown on a scientific balloon payload in May 2001. The detectors are both platinum-contact 10mm x 10mm x 5mm CZT crystals, each with a 4 $\times$ 4 array of pixels tiling the anode. One is made from IMARAD horizontal Bridgman CZT, the other from eV Products high-pressure Bridgman material. Both detectors were mounted side-by-side in a flip-chip configuration and read out by a 32-channel IDE VA/TA ASIC preamp/shaper. We enclosed the detectors in the same 40deg field-of-view collimator (comprisinga graded passive shield and plastic scintillator) used in our previously-reported September 2000 flight. I-V curves for the detectors are diode-like, and we find that the platinum contacts adhere significantly better to the CZT surfaces than gold to previous detectors. The detectors and instrumentation performed well in a 20-hour balloon flight on 23/24 May 2001. Although we discovered a significant instrumental background component in flight, it was possible to measure and subtract this component from the spectra. The resulting IMARAD detector background spectrum (from 30 keV to ~450 keV) reaches ~5 x 10^{-3}$ counts/cm^2 -sec-keV at 100 keV and has a power-law index of ~2 at high energies. The eV Products detector has a similar spectrum, although there is more uncertainty in the energy scale because of calibration complications.

No associations

LandOfFree

Say what you really think

Search LandOfFree.com for scientists and scientific papers. Rate them and share your experience with other people.

Rating

Background Measurements from Balloon-Borne CZT Detectors does not yet have a rating. At this time, there are no reviews or comments for this scientific paper.

If you have personal experience with Background Measurements from Balloon-Borne CZT Detectors, we encourage you to share that experience with our LandOfFree.com community. Your opinion is very important and Background Measurements from Balloon-Borne CZT Detectors will most certainly appreciate the feedback.

Rate now

     

Profile ID: LFWR-SCP-O-253441

  Search
All data on this website is collected from public sources. Our data reflects the most accurate information available at the time of publication.