ANN-based energy reconstruction procedure for TACTIC gamma-ray telescope and its comparison with other conventional methods

Astronomy and Astrophysics – Astrophysics – Instrumentation and Methods for Astrophysics

Scientific paper

Rate now

  [ 0.00 ] – not rated yet Voters 0   Comments 0

Details

23pages, 9 figures Accepted for publication in NIM A

Scientific paper

10.1016/j.nima.2009.04.012

The energy estimation procedures employed by different groups, for determining the energy of the primary $\gamma$-ray using a single atmospheric Cherenkov imaging telescope, include methods like polynomial fitting in SIZE and DISTANCE, general least square fitting and look-up table based interpolation. A novel energy reconstruction procedure, based on the utilization of Artificial Neural Network (ANN), has been developed for the TACTIC atmospheric Cherenkov imaging telescope. The procedure uses a 3:30:1 ANN configuration with resilient backpropagation algorithm to estimate the energy of a $\gamma$-ray like event on the basis of its image SIZE, DISTANCE and zenith angle. The new ANN-based energy reconstruction method, apart from yielding an energy resolution of $\sim$ 26%, which is comparable to that of other single imaging telescopes, has the added advantage that it considers zenith angle dependence as well. Details of the ANN-based energy estimation procedure along with its comparative performance with other conventional energy reconstruction methods are presented in the paper and the results indicate that amongst all the methods considered in this work, ANN method yields the best results. The performance of the ANN-based energy reconstruction has also been validated by determining the energy spectrum of the Crab Nebula in the energy range 1-16 TeV, as measured by the TACTIC telescope.

No associations

LandOfFree

Say what you really think

Search LandOfFree.com for scientists and scientific papers. Rate them and share your experience with other people.

Rating

ANN-based energy reconstruction procedure for TACTIC gamma-ray telescope and its comparison with other conventional methods does not yet have a rating. At this time, there are no reviews or comments for this scientific paper.

If you have personal experience with ANN-based energy reconstruction procedure for TACTIC gamma-ray telescope and its comparison with other conventional methods, we encourage you to share that experience with our LandOfFree.com community. Your opinion is very important and ANN-based energy reconstruction procedure for TACTIC gamma-ray telescope and its comparison with other conventional methods will most certainly appreciate the feedback.

Rate now

     

Profile ID: LFWR-SCP-O-322345

  Search
All data on this website is collected from public sources. Our data reflects the most accurate information available at the time of publication.