Astronomy and Astrophysics – Astrophysics – Instrumentation and Methods for Astrophysics
Scientific paper
2010-03-23
Astronomy and Astrophysics
Astrophysics
Instrumentation and Methods for Astrophysics
to be published in A&A, Main Journal (Astronomical Instrumentation)
Scientific paper
10.1051/0004-6361/200913686
Context. Accurate long-baseline interferometric measurements require careful calibration with reference stars. Small calibrators with high angular diameter accuracy ensure the true visibility uncertainty to be dominated by the measurement errors. Aims. We review some indirect methods for estimating angular diameter, using various types of input data. Each diameter estimate, obtained for the test-case calibrator star lambda Gru, is compared with the value 2.71 mas found in the Bord\'e calibrator catalogue published in 2002. Methods. Angular size estimations from spectral type, spectral index, in-band magnitude, broadband photometry, and spectrophotometry give close estimates of the angular diameter, with slightly variable uncertainties. Fits on photometry and spectrophotometry need physical atmosphere models with "plausible" stellar parameters. Angular diameter uncertainties were estimated by means of residual bootstrapping confidence intervals. All numerical results and graphical outputs presented in this paper were obtained using the routines developed under PV-WAVE, which compose the modular software suite SPIDAST, created to calibrate and interprete spectroscopic and interferometric measurements, particularly those obtained with VLTI-AMBER. Results. The final angular diameter estimate 2.70 mas of lambda Gru, with 68% confidence interval 2.65-2.81 mas, is obtained by fit of the MARCS model on the ISO-SWS 2.38-27.5 mum spectrum, with the stellar parameters T_eff = 4 250 K, log(g) = 2.0, z = 0.0 dex, M = 1.0 M_sun, and xi_turb = 2.0 km/s.
Bonneau Damien
Cruzalèbes Pierre
Jorissen Alain
Sacuto Stéphane
No associations
LandOfFree
Angular diameter estimation of interferometric calibrators - Example of lambda Gruis, calibrator for VLTI-AMBER does not yet have a rating. At this time, there are no reviews or comments for this scientific paper.
If you have personal experience with Angular diameter estimation of interferometric calibrators - Example of lambda Gruis, calibrator for VLTI-AMBER, we encourage you to share that experience with our LandOfFree.com community. Your opinion is very important and Angular diameter estimation of interferometric calibrators - Example of lambda Gruis, calibrator for VLTI-AMBER will most certainly appreciate the feedback.
Profile ID: LFWR-SCP-O-211394