Analysis, Dimensioning and Robust Control of Shunt Active Filter for Harmonic Currents Compensation in Electrical Mains

Computer Science – Systems and Control

Scientific paper

Rate now

  [ 0.00 ] – not rated yet Voters 0   Comments 0

Details

Paper presented at the AUTOMATICA_IT 2011 conference, Pisa, Italy, September 2011

Scientific paper

In this chapter some results related to Shunt Active Filters (SAFs) and obtained by the authors and some coauthors are reported. SAFs are complex power electronics equipments adopted to compensate for cur-rent harmonic pollution in electric mains, due to nonlinear loads. By using a proper "floating" capacitor as energy reservoir, the SAF purpose is to inject in the line grid currents canceling the polluting har-monics. Control algorithms play a key role for such devices and, in general, in many power electronics applications. Moreover, systems theory is crucial, since it is the mathematical tool that enables a deep understanding of the involved dynamics of such systems, allowing a correct dimensioning, beside an effective control. As a matter of facts, current injection objective can be straightforwardly formulated as an output tracking control problem. In this fashion, the structural and insidious marginally-stable internal/zero dynamics of SAFs can be immediately highlighted and characterized in terms of sizing and control issues. For what concerns the control design strictly, time-scale separation among output and internal dynamics can be effectively exploited to split the control design in different stages that can be later aggregated, by using singular perturbation analysis. In addition, for robust asymptotic output tracking the Internal Model Principle is adopted.

No associations

LandOfFree

Say what you really think

Search LandOfFree.com for scientists and scientific papers. Rate them and share your experience with other people.

Rating

Analysis, Dimensioning and Robust Control of Shunt Active Filter for Harmonic Currents Compensation in Electrical Mains does not yet have a rating. At this time, there are no reviews or comments for this scientific paper.

If you have personal experience with Analysis, Dimensioning and Robust Control of Shunt Active Filter for Harmonic Currents Compensation in Electrical Mains, we encourage you to share that experience with our LandOfFree.com community. Your opinion is very important and Analysis, Dimensioning and Robust Control of Shunt Active Filter for Harmonic Currents Compensation in Electrical Mains will most certainly appreciate the feedback.

Rate now

     

Profile ID: LFWR-SCP-O-14814

  Search
All data on this website is collected from public sources. Our data reflects the most accurate information available at the time of publication.