An Analysis of Future In-Flight Calibration of the GOES-O Solar X-Ray Imager using the Crab Nebula

Computer Science – Performance

Scientific paper

Rate now

  [ 0.00 ] – not rated yet Voters 0   Comments 0

Details

7554 X-Rays, Gamma Rays, And Neutrinos, 7924 Forecasting (2722)

Scientific paper

A potential in-flight calibration method for NOAA's Solar X-ray Imager (SXI), to be flown on the O-series Geostationary Operation Environmental Satellites (hereafter referred to as SXI-O), which uses the Crab nebula, is analyzed. Calculations of the Crab nebula's signal, Poisson noise and electronics noise are performed to determine the feasibility of future in-flight calibrations. Such calibration is necessary to aid in understanding instrument performance changes over time. Performance degradation is possible due to thin film filter failure, high voltage system changes, optical and detector contamination, and mechanism failures. Entrance filter and voltage system degradations have occurred on the SXI instrument on-board GOES-12, highlighting the need for accurate calibration techniques. Solar flares, which emit 1-8 angstrom X-rays, and subsequent solar phenomena, like coronal mass ejections, emit energy in the 6-60 angstrom X-ray range. This is also SXI-O's wavelength measurement requirement, and within the range of emission of one of the brightest astronomical X-ray sources, the Crab Nebula. Previous measurements of the Crab Nebula flux in the 6-60 angstrom range were made by the focal plane crystal spectrometer on the Einstein Observatory, and are used in this analysis. These signal and noise calculations integrate the wavelength dependant flux, taking into account components of SXI-O, which include the primary mirror, filters, detectors, and detector electronics. The sources of noise that are analyzed include the shot noise from the signal, the detector's dark current and charge transfer efficiency noise, the electronics read noise, and the quantization noise. The results of these analysis show that in-flight calibration of SXI-O using the Crab nebula is possible, and the longest single exposure of which the instrument is capable (65 sec) yields a signal to noise ratio somewhat insufficient to meet SXI-O's 20% photometric accuracy requirement. However, summing several 65 second images would increase the signal to noise ratio, making such a calibration readily possible.

No associations

LandOfFree

Say what you really think

Search LandOfFree.com for scientists and scientific papers. Rate them and share your experience with other people.

Rating

An Analysis of Future In-Flight Calibration of the GOES-O Solar X-Ray Imager using the Crab Nebula does not yet have a rating. At this time, there are no reviews or comments for this scientific paper.

If you have personal experience with An Analysis of Future In-Flight Calibration of the GOES-O Solar X-Ray Imager using the Crab Nebula, we encourage you to share that experience with our LandOfFree.com community. Your opinion is very important and An Analysis of Future In-Flight Calibration of the GOES-O Solar X-Ray Imager using the Crab Nebula will most certainly appreciate the feedback.

Rate now

     

Profile ID: LFWR-SCP-O-1108760

  Search
All data on this website is collected from public sources. Our data reflects the most accurate information available at the time of publication.