Alignment and performance of the Infrared Multi-Object Spectrometer

Computer Science – Performance

Scientific paper

Rate now

  [ 0.00 ] – not rated yet Voters 0   Comments 0

Details

Scientific paper

The Infrared Multi-Object Spectrometer (IRMOS) is a principle investigator class instrument for the Kitt Peak National Observatory 4 and 2.1 m telescopes. IRMOS is a near-IR (0.8 2.5 μm) spectrometer with low- to mid-resolving power (R = 300 3000). IRMOS produces simultaneous spectra of ~100 objects in its 2.8 ´ 2.0 arc-min field of view (4 m telescope) using a commercial Micro Electro-Mechanical Systems (MEMS) micro-mirror array (MMA) from Texas Instruments. The IRMOS optical design consists of two imaging subsystems. The focal reducer images the focal plane of the telescope onto the MMA field stop, and the spectrograph images the MMA onto the detector. We describe ambient breadboard subsystem alignment and imaging performance of each stage independently, and ambient imaging performance of the fully assembled instrument. Interferometric measurements of subsystem wavefront error serve as a qualitative alignment guide, and are accomplished using a commercial, modified Twyman-Green laser unequal path interferometer. Image testing provides verification of the optomechanical alignment method and a measurement of near-angle scattered light due to mirror small-scale surface error. Image testing is performed at multiple field points. A mercury-argon pencil lamp provides a spectral line at 546.1 nm, a blackbody source provides a line at 1550 nm, and a CCD camera and IR camera are used as detectors. We use commercial optical modeling software to predict the point-spread function and its effect on instrument slit transmission and resolution. Our breadboard and instrument level test results validate this prediction. We conclude with an instrument performance prediction for cryogenic operation and first light in late 2003.

No associations

LandOfFree

Say what you really think

Search LandOfFree.com for scientists and scientific papers. Rate them and share your experience with other people.

Rating

Alignment and performance of the Infrared Multi-Object Spectrometer does not yet have a rating. At this time, there are no reviews or comments for this scientific paper.

If you have personal experience with Alignment and performance of the Infrared Multi-Object Spectrometer, we encourage you to share that experience with our LandOfFree.com community. Your opinion is very important and Alignment and performance of the Infrared Multi-Object Spectrometer will most certainly appreciate the feedback.

Rate now

     

Profile ID: LFWR-SCP-O-1035740

  Search
All data on this website is collected from public sources. Our data reflects the most accurate information available at the time of publication.