Active flexure compensation software for the echellette spectrograph and imager on Keck II

Computer Science – Performance

Scientific paper

Rate now

  [ 0.00 ] – not rated yet Voters 0   Comments 0

Details

1

Scientific paper

All Cassegrain spectrographs suffer from gravitationally- induced flexure to some degree. While such flexure can be minimized via careful attention to mechanical design and fabrication, further performance improvements can be achieved if the spectrograph has been designed to minimize hysteresis and has active compensation for any residual flexure. The Echellette Spectrograph and Imager (ESI), built at UCO/Lick Observatory for use at Cassegrain focus on Keck II, compensates for such residual flexure via its collimator mirror. The collimator is driven by three actuators that provide control of collimator focus, tip, and tilt. The ESI control software utilizes a mathematical model of gravitationally-induced flexure to periodically compute and apply flexure corrections by commanding the corresponding tip and tilt motions to the collimator. In addition, the ESI control software provides an optional, manual, closed-loop method for adjusting the collimator position to compensate for any non-repeatable errors. Such errors may result from mechanical hysteresis or from thermally-induced structural deformations of the instrument and are thus not accounted for by the gravitational flexure model. This method relies on measuring the centroid position of fiducial spots within each echellete image. The collimator is adjusted so that the positions of these spots match those in a reference image. These spots are produced by a small round hole in the slit mask located near one end of the slit. We discuss the design and calibration of this flexure compensation system and report on its performance ont he telescope.

No associations

LandOfFree

Say what you really think

Search LandOfFree.com for scientists and scientific papers. Rate them and share your experience with other people.

Rating

Active flexure compensation software for the echellette spectrograph and imager on Keck II does not yet have a rating. At this time, there are no reviews or comments for this scientific paper.

If you have personal experience with Active flexure compensation software for the echellette spectrograph and imager on Keck II, we encourage you to share that experience with our LandOfFree.com community. Your opinion is very important and Active flexure compensation software for the echellette spectrograph and imager on Keck II will most certainly appreciate the feedback.

Rate now

     

Profile ID: LFWR-SCP-O-1248800

  Search
All data on this website is collected from public sources. Our data reflects the most accurate information available at the time of publication.