Achromatic lens systems for near infrared instruments. II. Performances and limitations of standard Flint glasses

Astronomy and Astrophysics – Astrophysics

Scientific paper

Rate now

  [ 0.00 ] – not rated yet Voters 0   Comments 0

Details

3

Instrumentation: Miscellaneous, Instrumentation: Spectrographs

Scientific paper

This paper investigates which normal Flint glasses are best suited for the design of lens systems working in the infrared up to about 1.7 mu m, and possibly up to 2.5 mu m. Between 0.9 and 2.5 mu m the best known achromatic pairs are BaF_2-IRG2 and SrF_2-IRG3 and, to a lesser extent, CaF_2-IRG7 (Oliva & Gennari 1995). Unfortunately, Schott will most probably stop the production of these very little used and commercially uninteresting IRG glasses. Here we show that equally good performances can be obtained coupling BaF_2 or SrF_2 with standard SF glasses. The pairs we analyze in details are BaF_2-SF6 and BaF_2-SF56A, and we also present new measurements of transmission for several SF glasses which are quite transparent up to 1.65 mu m and can be therefore readily employed in fiber-fed spectrographs and other instruments which do not extend beyond the H atmospheric window. At longer wavelengths the use of SF glasses is limited by strong water absorption features, but these could be eliminated by preparing the glass in vacuum environment. Although this production is expensive and commercially unattractive, we hope however that a large enough group of astronomers will support glass manufacturers in the production of ``IR-grade SF glasses''. As a practical application we present representative results of the design of F/2 (4 lenses) and F/1.4 (5 lenses) cameras for near infrared (0.95-2.5 mu m) spectrometers.

No associations

LandOfFree

Say what you really think

Search LandOfFree.com for scientists and scientific papers. Rate them and share your experience with other people.

Rating

Achromatic lens systems for near infrared instruments. II. Performances and limitations of standard Flint glasses does not yet have a rating. At this time, there are no reviews or comments for this scientific paper.

If you have personal experience with Achromatic lens systems for near infrared instruments. II. Performances and limitations of standard Flint glasses, we encourage you to share that experience with our LandOfFree.com community. Your opinion is very important and Achromatic lens systems for near infrared instruments. II. Performances and limitations of standard Flint glasses will most certainly appreciate the feedback.

Rate now

     

Profile ID: LFWR-SCP-O-1656135

  Search
All data on this website is collected from public sources. Our data reflects the most accurate information available at the time of publication.