Absolute radiometric calibration of the EUNIS-06 170-205 A channel and calibration update for CDS/NIS

Astronomy and Astrophysics – Astrophysics – Instrumentation and Methods for Astrophysics

Scientific paper

Rate now

  [ 0.00 ] – not rated yet Voters 0   Comments 0

Details

11 pages, 10 figures, 4 tables. 2010, ApJ Suppl. In press

Scientific paper

10.1088/0067-0049/186/2/222

The Extreme-Ultraviolet Normal-Incidence Spectrograph sounding-rocket payload was flown on 2006 April 12 (EUNIS-06), carrying two independent imaging spectrographs covering wave bands of 300-370 A in first order and 170-205 A in second order, respectively. The absolute radiometric response of the EUNIS-06 long-wavelength (LW) channel was directly measured in the same facility used to calibrate CDS prior to the SOHO launch. Because the absolute calibration of the short-wavelength (SW) channel could not be obtained from the same lab configuration, we here present a technique to derive it using a combination of solar LW spectra and density- and temperature-insensitive line intensity ratios. The first step in this procedure is to use the coordinated, cospatial EUNIS and SOHO/CDS spectra to carry out an intensity calibration update for the CDS NIS-1 waveband, which shows that its efficiency has decreased by a factor about 1.7 compared to that of the previously implemented calibration. Then, theoretical insensitive line ratios obtained from CHIANTI allow us to determine absolute intensities of emission lines within the EUNIS SW bandpass from those of cospatial CDS/NIS-1 spectra after the EUNIS LW calibration correction. A total of 12 ratios derived from intensities of 5 CDS and 12 SW emission lines from Fe Fe X - Fe XIII yield an instrumental response curve for the EUNIS-06 SW channel that matches well to a relative calibration which relied on combining measurements of individual optical components. Taking into account all potential sources of error, we estimate that the EUNIS-06 SW absolute calibration is accurate to about 20%.

No associations

LandOfFree

Say what you really think

Search LandOfFree.com for scientists and scientific papers. Rate them and share your experience with other people.

Rating

Absolute radiometric calibration of the EUNIS-06 170-205 A channel and calibration update for CDS/NIS does not yet have a rating. At this time, there are no reviews or comments for this scientific paper.

If you have personal experience with Absolute radiometric calibration of the EUNIS-06 170-205 A channel and calibration update for CDS/NIS, we encourage you to share that experience with our LandOfFree.com community. Your opinion is very important and Absolute radiometric calibration of the EUNIS-06 170-205 A channel and calibration update for CDS/NIS will most certainly appreciate the feedback.

Rate now

     

Profile ID: LFWR-SCP-O-532597

  Search
All data on this website is collected from public sources. Our data reflects the most accurate information available at the time of publication.