Absolute Flux Calibration for STIS First-Order, Low-Resolution Modes

Computer Science

Scientific paper

Rate now

  [ 0.00 ] – not rated yet Voters 0   Comments 0

Details

Hubble Space Telescope, Hst, Space Telescope Science Institute, Stis, Space Telescope Imaging Spectrograph

Scientific paper

Point source sensitivity curves are derived for the first order modes G140L, G230L, G230LB, G430L, and G750L, which collectively span a wavelength range from 1140Å to 10320Å. The curves are determined by comparing wide slit (52" x 2") observations of the spectrophotometric standard star GD153 to a pure hydrogen white dwarf model. The calibration is checked by comparing a calibrated STIS observation of the spectrophotometric standard star G191B2B to its pure hydrogen model. Except for G140L, there is no good evidence for changes in the sensitivity beyond ~1% through the end of 1997. Except for the G140L and the long wavelength part of G750L, the absolute flux calibration is accurate for observations in 1997 to ~3% for stars centered in the 52x2" slit. Preliminary results on the vignetting analysis for the first order modes suggest that the smooth changes in sensitivity as a function of distance along the slit are less than ±2 % for all first order modes, except for the extremities of G140L, where 5% differences in detector QE are observed. While the 52x2" slit is ideal for photometric continuum determinations, a narrower slit should be used for line profile measurements in order to minimize the contamination from the impure light in the wings of the PSF. For the narrowest slits, local inhomogeneities in the slit width cause a variable throughput along the slit (see the STIS Foibles page on the STIS Instrument WWW pages).

No associations

LandOfFree

Say what you really think

Search LandOfFree.com for scientists and scientific papers. Rate them and share your experience with other people.

Rating

Absolute Flux Calibration for STIS First-Order, Low-Resolution Modes does not yet have a rating. At this time, there are no reviews or comments for this scientific paper.

If you have personal experience with Absolute Flux Calibration for STIS First-Order, Low-Resolution Modes, we encourage you to share that experience with our LandOfFree.com community. Your opinion is very important and Absolute Flux Calibration for STIS First-Order, Low-Resolution Modes will most certainly appreciate the feedback.