Astronomy and Astrophysics – Astrophysics
Scientific paper
Apr 2002
adsabs.harvard.edu/cgi-bin/nph-data_query?bibcode=2002aps..aprn17021b&link_type=abstract
American Physical Society, April Meeting, Jointly Sponsored with the High Energy Astrophysics Division (HEAD) of the American As
Astronomy and Astrophysics
Astrophysics
Scientific paper
We have used the NASA/GSFC engineering model Astro-E microcalorimeter 6x6 array with the LLNL electron beam ion trap uc(ebit-i) to measure absolute excitation cross sections of Fe uc(xvii) L-shell x-ray transitions by normalizing to radiative recombination (RR). In the past, normalizing Fe uc(xvii) L-shell transitions to RR has not been possible because it is approximately 1000 times weaker than direct excitation, its emission often blends with emission from other charge states, and it is separated from direct excitation by greater than 500 eV. However, because of its large effective area, high resolution, large bandwidth, and long-time gain stability, the spare Astro-E microcalorimeter coupled with uc(ebit-i) has made measurement of absolute cross sections of Fe uc(xvii) L-shell transitons possible. We present the measured cross sections of two of the strongest lines observed in a plethora of astrophysical sources, the Fe uc(xvii) resonance and intercombination lines, located at 15.01 Å and 15.26 Årespectively. Our results provide stringent tests for atomic data present in spectral modeling packages and can be used to interpret high-resolution spectra provided by the Chandra X-Ray Observatory, XMM-Newton, and, in the near future, Astro-E2. Work by the UC-LLNL was performed under auspices of DOE under contract No. W-7405-Eng-48 and supported by NASA SARA grants to LLNL, GSFC, and Columbia University.
Beiersdorfer Peter
Boyce Kevin R.
Brown Garfield
Chen Haibin
Kahn Steve M.
No associations
LandOfFree
Absolute Cross sections of Fe XVII x-ray transitions measured with the spare Astro-E microcalorimeter Array does not yet have a rating. At this time, there are no reviews or comments for this scientific paper.
If you have personal experience with Absolute Cross sections of Fe XVII x-ray transitions measured with the spare Astro-E microcalorimeter Array, we encourage you to share that experience with our LandOfFree.com community. Your opinion is very important and Absolute Cross sections of Fe XVII x-ray transitions measured with the spare Astro-E microcalorimeter Array will most certainly appreciate the feedback.
Profile ID: LFWR-SCP-O-1537212