Absolute Calibration of the Infrared Array Camera on the Spitzer Space Telescope

Astronomy and Astrophysics – Astrophysics

Scientific paper

Rate now

  [ 0.00 ] – not rated yet Voters 0   Comments 0

Details

accepted to PASP; 7/7/05: fixed mistake on page 17 (extended source corrections must be multiplied not divided)

Scientific paper

10.1086/432670

The Infrared Array Camera (IRAC) on the Spitzer Space Telescope is absolutely calibrated by comparing photometry on a set of A stars near the north ecliptic pole to predictions based on ground-based observations and a stellar atmosphere model. The brightness of point sources is calibrated to an accuracy of 3%, relative to models for A star stellar atmospheres, for observations performed and analyzed in the same manner as the calibration stars. This includes corrections for location of the star in the array and the location if the centroid within the peak pixel. Long-term stability of the IRAC photometry was measured by monitoring the brightness of A dwarfs and K giants (near the north ecliptic pole) observed several times per month; the photometry is stable to 1.5% (rms) over a year. Intermediate-time-scale stability of the IRAC photometry was measured by monitoring at least one secondary calibrator (near the ecliptic plane) every 12 hr while IRAC is in nominal operations; the intermediate-term photometry is stable with a 1% dispersion (rms). One of the secondary calibrators was found to have significantly time-variable (5%) mid-infrared emission, with period (7.4 days) matching the optical light curve; it is possibly a Cepheid variable.

No associations

LandOfFree

Say what you really think

Search LandOfFree.com for scientists and scientific papers. Rate them and share your experience with other people.

Rating

Absolute Calibration of the Infrared Array Camera on the Spitzer Space Telescope does not yet have a rating. At this time, there are no reviews or comments for this scientific paper.

If you have personal experience with Absolute Calibration of the Infrared Array Camera on the Spitzer Space Telescope, we encourage you to share that experience with our LandOfFree.com community. Your opinion is very important and Absolute Calibration of the Infrared Array Camera on the Spitzer Space Telescope will most certainly appreciate the feedback.

Rate now

     

Profile ID: LFWR-SCP-O-611081

  Search
All data on this website is collected from public sources. Our data reflects the most accurate information available at the time of publication.