A STIS Survey for OVI Absorption Systems at 0.12 < z < 0.5 I.: The Statistical Properties of Ionized Gas

Astronomy and Astrophysics – Astrophysics

Scientific paper

Rate now

  [ 0.00 ] – not rated yet Voters 0   Comments 0

Details

12 pages. ApJ accepted

Scientific paper

10.1086/587976

We have conducted a systematic survey for intervening OVI absorbers in available echelle spectra of 16 QSOs at z_QSO = 0.17-0.57. These spectra were obtained using HST/STIS with the E140M grating. Our search uncovered a total of 27 foreground OVI absorbers with rest-frame absorption equivalent width W_r(1031) > 25mA. Ten of these QSOs exhibit strong OVI absorbers in their vicinity. Our OVI survey does not require the known presence of Lya, and the echelle resolution allows us to identify the OVI absorption doublet based on their common line centroid and known flux ratio. We estimate the total redshift survey path, \Delta z, using a series of Monte-Carlo simulations, and find that \Delta z=1.66, 2.18, and 2.42 for absorbers of strength W_r = 30, 50 and 80mA, respectively, leading to a number density of dN(W > 50mA)/dz = 6.7 +/- 1.7 and dN(W > 30mA)/dz = 10.4 +/- 2.2. In contrast, we also measure dN/dz = 27 +/- 9 for OVI absorbers of W_r > 50mA at |\Delta v|< 5000 kms from the background QSOs. Using the random sample of OVI absorbers with well characterized survey completeness, we estimate a mean cosmological mass density of the OVI gas \Omega(OVI)h = 1.7 +/- 0.3 x 10^-7. In addition, we show that <5% of OVI absorbers originate in underdense regions that do not show a significant trace of HI. Furthermore, we show that the neutral gas column N(HI) associated with these OVI absorbers spans nearly five orders of magnitude, and show moderate correlation with N(OVI). Finally, while the number density of OVI absorbers varies substantially from one sightline to another, it also appears to be inversely correlated with the number density of HI absorbers along individual lines of sight.

No associations

LandOfFree

Say what you really think

Search LandOfFree.com for scientists and scientific papers. Rate them and share your experience with other people.

Rating

A STIS Survey for OVI Absorption Systems at 0.12 < z < 0.5 I.: The Statistical Properties of Ionized Gas does not yet have a rating. At this time, there are no reviews or comments for this scientific paper.

If you have personal experience with A STIS Survey for OVI Absorption Systems at 0.12 < z < 0.5 I.: The Statistical Properties of Ionized Gas, we encourage you to share that experience with our LandOfFree.com community. Your opinion is very important and A STIS Survey for OVI Absorption Systems at 0.12 < z < 0.5 I.: The Statistical Properties of Ionized Gas will most certainly appreciate the feedback.

Rate now

     

Profile ID: LFWR-SCP-O-159291

  Search
All data on this website is collected from public sources. Our data reflects the most accurate information available at the time of publication.