A gravitational microlensing determination of continuum source size in Q2237+0305

Astronomy and Astrophysics – Astrophysics

Scientific paper

Rate now

  [ 0.00 ] – not rated yet Voters 0   Comments 0

Details

7 pages, 5 figures. Accepted for publication in Monthly Notices of the Royal Astronomical Society. Revised version has improve

Scientific paper

10.1046/j.1365-8711.2000.03361.x

Following the detection of a gravitational microlensing high magnification event (HME) in Q2237+0305A attempts have been made to place limits on the dimensions of the quasar continuum source. The analyses have studied either the observed event magnitude or the event duration. The latter approach has been hampered by lack of knowledge about the transverse velocity of the lensing galaxy. We obtain both upper and lower statistical limits on the size of the continuum source from the observed HME using determinations of transverse velocity obtained from the published monitoring data. Our calculations take account of the caustic orientation as well as the component of the caustic velocity that results from stellar proper motions. Our determination of source size relies on an estimated duration of 52 days for the HME, and so will be refined when more HMEs are observed. We find that the upper and lower limits on the magnified region of the R-band continuum source are 6 times 10^15 and 2 times 10^13 cm respectively (99% confidence). Through consideration of the joint probability for source size and mean microlens mass we find that the mean mass lies between ~0.01 solar masses and ~1 solar mass (95% confidence).

No associations

LandOfFree

Say what you really think

Search LandOfFree.com for scientists and scientific papers. Rate them and share your experience with other people.

Rating

A gravitational microlensing determination of continuum source size in Q2237+0305 does not yet have a rating. At this time, there are no reviews or comments for this scientific paper.

If you have personal experience with A gravitational microlensing determination of continuum source size in Q2237+0305, we encourage you to share that experience with our LandOfFree.com community. Your opinion is very important and A gravitational microlensing determination of continuum source size in Q2237+0305 will most certainly appreciate the feedback.

Rate now

     

Profile ID: LFWR-SCP-O-54034

  Search
All data on this website is collected from public sources. Our data reflects the most accurate information available at the time of publication.