The quantum system of the passive hydrogen maser is introduced briefly and a design of the spectrum observing device is expounded. The 10 MHz crystal oscillator is adopted to supply the passive hydrogen maser with microwave signal (1.420406 GHz) which is input to the maser oscillator. The output signal from the maser oscillator is amplified with low noise, mixed twice and filtered, and the final spectrum which contains the information of quantum system is analysed so as to help one to learn the quantum system's performance. The spectrum observing device has been applied to the tests of two passive hydrogen masers and the quantum systems have been improved based on the tests.
Lin Chuan-Fu
Shao Yan-Li
Zhang Jun-Hai
No associations
LandOfFree
A design of observing device for hyperfine transition spectrum of passive hydrogen maser does not yet have a rating. At this time, there are no reviews or comments for this scientific paper.
If you have personal experience with A design of observing device for hyperfine transition spectrum of passive hydrogen maser, we encourage you to share that experience with our LandOfFree.com community. Your opinion is very important and A design of observing device for hyperfine transition spectrum of passive hydrogen maser will most certainly appreciate the feedback.