A comparison of measured and calculated toroidal Alfvén eigenmode damping rates in Alcator C-Mod

Computer Science

Scientific paper

Rate now

  [ 0.00 ] – not rated yet Voters 0   Comments 0

Details

7

Scientific paper

Measured damping rates of stable toroidal Alfvén eigenmodes (TAEs) have been compared with damping rates calculated with the NOVA-K code for a number of experimental conditions on Alcator C-Mod to test the NOVA-K damping model. Very low amplitude ( \tilde{B}_\theta/B_\theta \sim 10-7 at the wall) stable TAEs are excited in Ohmic plasmas with a pair of active MHD antennas inside C-Mod. By sweeping the excited frequency of the antennas through the expected TAE frequency, the frequency width of a mode resonance can be measured with poloidal field pick-up coils on outboard limiters to determine the damping rate of that mode. The calculated equilibrium and main plasma parameters at the time of the resonance are input into the NOVA-K code to then calculate the expected damping rate for the measured toroidal mode number and compare with the experimental value. The calculations include continuum damping, Landau damping on both the electrons and the background and impurity ions and collisional damping on the electrons. Comparisons have been made for inner wall limited and diverted cases over a range of ITER-relevant moderate toroidal mode numbers (4 <= |n | <= 9). Good agreement between the experiment and theoretical calculations can be obtained with reasonable q profiles for the plasma conditions in which perturbative NOVA models are applicable, but the results are found to depend very sensitively on the assumed q profile.

No associations

LandOfFree

Say what you really think

Search LandOfFree.com for scientists and scientific papers. Rate them and share your experience with other people.

Rating

A comparison of measured and calculated toroidal Alfvén eigenmode damping rates in Alcator C-Mod does not yet have a rating. At this time, there are no reviews or comments for this scientific paper.

If you have personal experience with A comparison of measured and calculated toroidal Alfvén eigenmode damping rates in Alcator C-Mod, we encourage you to share that experience with our LandOfFree.com community. Your opinion is very important and A comparison of measured and calculated toroidal Alfvén eigenmode damping rates in Alcator C-Mod will most certainly appreciate the feedback.

Rate now

     

Profile ID: LFWR-SCP-O-1550835

  Search
All data on this website is collected from public sources. Our data reflects the most accurate information available at the time of publication.