A capacitive bubble level and its application on the transit instrument

Astronomy and Astrophysics – Astrophysics

Scientific paper

Rate now

  [ 0.00 ] – not rated yet Voters 0   Comments 0

Details

Scientific paper

A bubble level based on a capacitive transducer is described. The transducer consists of four pieces of tin-foil stuck on the surface of the bubble level, forming two capacitors. By measuring the capacitive difference between the two, the position of the bubble level can be found. It has a measuring range of 12''/. and an accuracy of +/-0''/.1. It is compatible with visual reading and lends itself readily to digitization and automation. When used on the transit instrument the personal equation in the time determination was greatly reduced (from +/-3.9 ms to +/-1.1 ms in one test).

No associations

LandOfFree

Say what you really think

Search LandOfFree.com for scientists and scientific papers. Rate them and share your experience with other people.

Rating

A capacitive bubble level and its application on the transit instrument does not yet have a rating. At this time, there are no reviews or comments for this scientific paper.

If you have personal experience with A capacitive bubble level and its application on the transit instrument, we encourage you to share that experience with our LandOfFree.com community. Your opinion is very important and A capacitive bubble level and its application on the transit instrument will most certainly appreciate the feedback.