A 1.2--Millimeter Broad--Band Polarimeter

Computer Science – Performance

Scientific paper

Rate now

  [ 0.00 ] – not rated yet Voters 0   Comments 0

Details

Scientific paper

We describe a 1.2--millimeter polarimeter to be used on the Steward Observatory and Max--Planck--Institut fur Radioastronomie 10--meter Submillimeter Telescope Observatory. The construction, performance parameters, and scientific purpose of the instrument are presented. The detector is a Ge bolometer with a Si absorber operated in a cavity cooled to 0.36 K by a liquid He(3) refrigerator. The bandpass has a central wavelength of 1.2 mm and a width of 0.3 mm. The system noise equivalent power is 1.5*E(-14) W Hz(-{1/2}) at 20 Hz. Polarimetric modulation is accomplished with a room temperature, rotating Rexolite half-wave plate. Unidirectional grooves provide the lambda /2 phase shift between the orthogonal senses of polarization. The polarization analyzer is a stationary, room temperature, unidirectional wire grid that transmits only one sense of polarization with 99% efficiency. The system polarimetric efficiency is 87% and the laboratory instrumental polarization is a well defined 3.7%. Detection of a 1% linear polarization is possible at the several sigma level. The primary scientific goal of this instrument is to probe the magnetic field orientations in the protostellar dust cores of molecular clouds. Non--spherical dust grains are aligned in the presence of a magnetic field resulting in linear polarization of the far--infrared thermal dust emission perpendicular to the magnetic field vector. Observed field orientations will be compared to protostellar molecular outflow orientations and magnetic fields on larger scales. With these comparisons we will assess the role of magnetic fields in cloud collapse and star formation.

No associations

LandOfFree

Say what you really think

Search LandOfFree.com for scientists and scientific papers. Rate them and share your experience with other people.

Rating

A 1.2--Millimeter Broad--Band Polarimeter does not yet have a rating. At this time, there are no reviews or comments for this scientific paper.

If you have personal experience with A 1.2--Millimeter Broad--Band Polarimeter, we encourage you to share that experience with our LandOfFree.com community. Your opinion is very important and A 1.2--Millimeter Broad--Band Polarimeter will most certainly appreciate the feedback.

Rate now

     

Profile ID: LFWR-SCP-O-1354497

  Search
All data on this website is collected from public sources. Our data reflects the most accurate information available at the time of publication.