3C 286: a bright, compact, stable, and highly polarized calibrator for millimeter-wavelength observations

Astronomy and Astrophysics – Astrophysics – Instrumentation and Methods for Astrophysics

Scientific paper

Rate now

  [ 0.00 ] – not rated yet Voters 0   Comments 0

Details

Accepted for publication in A&A. 7 pages, 4 figures, 8 tables. Updated data sets with regard to previous version. New discussi

Scientific paper

(Context.) A number of millimeter and submillimeter facilities with linear polarization observing capabilities have started operating during last years. These facilities, as well as other previous millimeter telescopes and interferometers, require bright and stable linear polarization calibrators to calibrate new instruments and to monitor their instrumental polarization. The current limited number of adequate calibrators implies difficulties in the acquisition of these calibration observations. (Aims.) Looking for additional linear polarization calibrators in the millimeter spectral range, in mid-2006 we started monitoring 3C 286, a standard and highly stable polarization calibrator for radio observations. (Methods.) Here we present the 3 and 1 mm monitoring observations obtained between September 2006 and January 2012 with the XPOL polarimeter on the IRAM 30 m Millimeter Telescope. (Results.) Our observations show that 3C 286 is a bright source of constant total flux with 3 mm flux density S_3mm = (0.91 \pm 0.02) Jy. The 3mm linear polarization degree (p_3mm =[13.5\pm0.3]%) and polarization angle (chi_3mm =[37.3\pm0.8]deg.,expressed in the equatorial coordinate system) are also constant during the time span of our observations. Although with poorer time sampling and signal-to-noise ratio, our 1 mm observations of 3C 286 are also reproduced by a constant source of 1 mm flux density (S_1mm = [0.30 \pm 0.03] Jy), polarization fraction (p_1mm = [14.4 \pm 1.8] %), and polarization angle (chi_1mm = [33.1 \pm 5.7]deg.). (Conclusions.) This, together with the previously known compact structure of 3C 286 -extended by ~3.5" in the sky- allow us to propose 3C 286 as a new calibrator for both single dish and interferometric polarization observations at 3 mm, and possibly at shorter wavelengths.

No associations

LandOfFree

Say what you really think

Search LandOfFree.com for scientists and scientific papers. Rate them and share your experience with other people.

Rating

3C 286: a bright, compact, stable, and highly polarized calibrator for millimeter-wavelength observations does not yet have a rating. At this time, there are no reviews or comments for this scientific paper.

If you have personal experience with 3C 286: a bright, compact, stable, and highly polarized calibrator for millimeter-wavelength observations, we encourage you to share that experience with our LandOfFree.com community. Your opinion is very important and 3C 286: a bright, compact, stable, and highly polarized calibrator for millimeter-wavelength observations will most certainly appreciate the feedback.

Rate now

     

Profile ID: LFWR-SCP-O-463894

  Search
All data on this website is collected from public sources. Our data reflects the most accurate information available at the time of publication.