The design and construction of 100 mK composite bolometers for low background submillimeter and millimeter-wave astronomy are discussed. The bolometers are cooled to 100 mK using an adiabatic demagnetization refrigerator. The bolometers consist of a silicon substrate suspended by nylon fibers, a bismuth film absorber, a neutron transmutation doped germanium thermometer with graphite fiber electrical leads, and a brass wire thermal strap. Heated JFET amplifiers located on the 1.5 K cold plate are used to read out the bolometer signals. Electrically measured noise equivalent powers as low as 2 X 10(superscript -17) W/(root)Hz have been achieved.
Clapp Andre
Devlin Mark J.
Fischer Marc L.
Hagmann Chris
Lange Andrew E.
No associations
LandOfFree
100-mK bolometric receiver for low-background astronomy does not yet have a rating. At this time, there are no reviews or comments for this scientific paper.
If you have personal experience with 100-mK bolometric receiver for low-background astronomy, we encourage you to share that experience with our LandOfFree.com community. Your opinion is very important and 100-mK bolometric receiver for low-background astronomy will most certainly appreciate the feedback.