Small-area fiber-coupled scintillation camera for imaging beta-ray distributions intraoperatively

Computer Science

Scientific paper

Rate now

  [ 0.00 ] – not rated yet Voters 0   Comments 0

Details

Scientific paper

A small area, imaging, scintillation probe is being developed for locating small amounts of radio-labeled malignant tissue during surgery. Preliminary in brain surgery, avoiding the removal of excess tissue is a priority. It is possible to locate the main body of a brain tumor both before and during surgery, but once the bulk of the tumor is excised the identification of residual malignant tissue is difficult. A probe that covers an area of 1-2 cm(superscript 2) with an intrinsic resolution of 1-2 mm could locate small tumor masses that pose a threat of recurrence of the disease, and prevent removal of healthy tissue. A pre-operative injection of tumor seeking, beta emitting radiopharmaceutical (e.g. (superscript 18)fluorodeoxyuridine-FDUR-) will label the tumor. The limited range of beta-rays ensures proximity upon successful detection. Plastic scintillators are used for beta detection, and visible light photon counters (VLPCs) detect the scintillation light. For maneuverability in and around the surgical cavity, the scintillators are coupled to the VLPCs via 2 m of optical fiber. An imaging device can cover the tissue bed in a time compatible with surgery, as opposed to a single element detector on the order of 1-2 mm in size with comparable resolution. An imager also distinguishes high background rates (such as from annihilation gammas in FDUR) and concentrations of activity.

No associations

LandOfFree

Say what you really think

Search LandOfFree.com for scientists and scientific papers. Rate them and share your experience with other people.

Rating

Small-area fiber-coupled scintillation camera for imaging beta-ray distributions intraoperatively does not yet have a rating. At this time, there are no reviews or comments for this scientific paper.

If you have personal experience with Small-area fiber-coupled scintillation camera for imaging beta-ray distributions intraoperatively, we encourage you to share that experience with our LandOfFree.com community. Your opinion is very important and Small-area fiber-coupled scintillation camera for imaging beta-ray distributions intraoperatively will most certainly appreciate the feedback.

Rate now

     

Profile ID: LFWR-SCP-O-991043

  Search
All data on this website is collected from public sources. Our data reflects the most accurate information available at the time of publication.